Dongguan Yifan Instrument Co., Ltd
Home>Products>Battery Thermal Shock Test Chamber YF-6009
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13924354939
  • Address
    No.1 Pailouji Industrial Road, Wanjiang Street, Dongguan City, Guangdong Province
Contact Now
Battery Thermal Shock Test Chamber YF-6009
Product Overview: The battery thermal shock test chamber simulates the battery being placed in a high-temperature chamber with natural convection or f
Product details

Product Overview:

The battery thermal shock test chamber simulates the battery being placed in a high-temperature chamber with natural convection or forced ventilation. It heats up to the set test temperature at a certain heating rate and maintains it for a certain period of time. It uses a hot air circulation system to ensure uniform distribution of working temperature.

Meet the standards:

GB/T 31485-2015,GB/T 31241-2014,UN38.3,IEC62133,QC/T743-201X,GB/T 8897.4-2008,GB/T 21966-2008

Technical Specifications:

1. Inner box size: 400x400x450mm (width x depth x height)

2. Outer box size: 650x510x1280mm (width x depth x height)

3. Temperature range: normal temperature~200 ℃

5. Temperature display accuracy: 0.1 ℃

6. Temperature stability: ± 1.0 ℃

7. Temperature uniformity: ± 2 ℃

8. Heating time: (5 ± 2) ℃/min, (average heating, non-linear no-load)

9. Temperature controller: Programmable temperature controller that can control the total heating time, different from ordinary temperature controllers.

10. Inner box material: stainless steel plate

11. Outer box material: Cold rolled steel plate baked paint

12. Insulation material: high-efficiency compressed glass wool

13. Thermal insulation device: no fuse switch, over temperature protection switch, fuse

14. Power supply: 1 ∧, 220V, 20A

15. Safety devices: secondary over temperature alarm, MCCB overload protection, etc

16. Exhaust flue: blade design with adjustable air volume

17. Control formation: After the temperature of the battery thermal shock test chamber reaches the set temperature, the timer will automatically turn on. When the time is up, the heating power supply will be cut off, and a buzzing prompt will sound

18. Supply air circulation system: convective supply air circulation system

19. Control system: temperature up timer, time down shutdown, buzzer prompt.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!