Product Overview:
This machine is suitable for simulating the needle puncture situation of various batteries during transportation and storage. The experiment should be conducted at an ambient temperature of 20 ℃± 5 ℃. The battery connected to the thermocouple (with the thermocouple contacts fixed on the large surface of the battery) should be placed in a fume hood, and a corrosion-resistant steel needle with a diameter of 2-8mm should be used to pierce the center position of the maximum surface of the battery at a speed of 10mm/s to 40mm/s. The test results should be observed for any time, and if the battery does not explode or ignite, it is considered qualified.
Meet the standards:
GB 31241-2014,GB/T 8897.4-2008,YD/T 2344.1-2011,GB/T 21966-2008,MT/T 1051-2007,YD 1268-2003,GB/T 19521.11-2005,YDB 032-2009,UL 1642,UL 2054,IEC 62281,IEC 60086
Technical Specifications:
1. Steel needle: High temperature resistant steel needle with a diameter of 5mm to 8mm, with a length of 100mm
2. Acupuncture stroke: 200mm (customizable)
3. Clamp battery distance: 200mm
4. Unit conversion: Kg, N, LB
5. Acupuncture speed: 10-40mm/s
6. Acupuncture force value: 1-300Kg
7. Force value display: LCD display or touch screen display
8. Force measurement accuracy: ± 1%
9. Drive mode: cylinder drive
10. Box material: Inner box made of stainless steel, outer box made of cold-rolled steel plate with spray coating treatment
11. Features: The rear side of the box is designed with exhaust vents, and the box is equipped with lighting fixtures
12. Weight: Approximately 100kg
13. Power supply: 1 ∧, 220V, 50HZ