1. Temperature range: ambient temperature plus 5 ℃ to 300 ℃

2 APT.line ™ Preheating chamber technology

3. Adjustable fan speed

4. Adjustable exhaust valve

5. Controller using interval programming and real-time programming

6. 2 chrome plated sockets

7. Independent adjustable temperature safety device level 2 (DIN 12880) with optical alarm

8. Computer interface: RS 422

2、 Technical parameters:

Product Model FP053-230V1 FP053UL-120V1
Choose a model standard standard
Item code 9010-0153 9010-0175
measurement
Internal volume [L] 53 53
Net weight of equipment (unloaded) [kg] 44 44
Maximum total load [kg] 40 40
Maximum load per partition [kg] 15 15
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 635 635
Net weight at height [mm] 620 620
Depth net weight [mm] 575 575
Wall distance from rear [mm] 160 160
Wall to side distance [mm] 100 100
internal dimensions
Width [mm] 400 400
Height [mm] 400 400
Depth [mm] 340 340
Data related to the environment
Energy consumption at 150 ℃ [Wh/h] 300 300
firmware
Number of partitions (hours/maximum) 2/5 2/5
Temperature performance data
The temperature range exceeds the indoor temperature by 5 ℃ to [℃] 300 300
Temperature deviation is 150 ℃ [± K] 2 2
Temperature fluctuation at 150 ℃ [± K] 0.3 0.3
Heating time to 150 ℃ [min] 24 24
The recovery time after opening the door in 30 seconds is 150 ℃ [min] 5 5
Ventilation data
Air exchange rate at 150 ℃ [x/h] 64 64
Electric data
Rated voltage [V] 230 120
Power frequency [Hz] 50/60 60
Rated power [kW] 1.2 1.2
Equipment safety device [A] 10 16
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.