BD/SN-900Water cooled type6.5KWXenon lamp aging test chamber
Product principle: This product can simulate various environmental factors such as lighting, rain, temperature and humidity, condensation, etc., and can be independently adjusted; Xenon lamps are used as light sources, which have a spectral distribution similar to sunlight. Therefore, in science, xenon lamp light is used to simulate sunlight for lighting experiments; Mainly used in products such as paints, coatings, rubber, plastics, pigments, adhesives, fabrics, cosmetics, etc.
1、 Product Model and Parameters
PRODUCT MODEL |
BD/SN-900 |
Internal dimensionsD×W×Hmm |
950×950×850 |
External dimensionsD×W×Hmm |
1460×1280×1950 |
temperature range |
RT+10℃~70℃ |
Humidity range |
60%~98% R.H |
Black panel temperature |
63℃~100℃±3℃ |
temperature fluctuation |
≤±0.5℃ |
temperature uniformity |
≤±2℃ |
Humidity fluctuation |
+2、-3% R.H |
Xenon lamp source |
Water-cooled lamp tube |
Lamp wattage |
6.5KW |
Total number of lamps |
2Branch (including1Support backup) |
Lamp lifespan |
800~1000hour |
Glass filter cover |
1cover |
Rainfall time |
0~9999minContinuous rainfall adjustable |
Rainfall cycle |
0~240minInterval (interval) rainfall adjustable |
Spray cycle |
18min/102minperhaps12min/48min(Spray time)/Non spraying time |
Rainwater pressure |
0.12~0.15Mpa |
Spray nozzle aperture |
Ф0.8mm |
Power |
2KW |
Humidification power |
1.5KW |
Distance between sample rack and lamp tube |
300~375mm |
Sample test rack |
diameter800mm,360Degree rotation, rotation rate1-4change/min |
Standard sample size |
75mm×150mmStandard template |
spectral wavelength |
280nm~800nm |
Continuous adjustable light cycle time |
0~999H、M、S |
radiance |
The full spectrum irradiance is550 W/m2Or340nmThe irradiance at this location is0.3-1.0 W/m2 |
Power requirements |
AC380(±10%)V/50HZThree-phase five-wire system |
Product features: The xenon lamp tube is vertically installed at the center of the box, and a rotary drum type sample holder is installed around the lamp tube. There are several standard fixtures on the sample holder. During equipment operation, the sample holder rotates around the lamp tube to ensure uniform irradiation at each angle. So the water-cooled xenon lamp aging test chamber is suitable for thin or sliced samples.
Reference standards
GB/T16422.2-1999Plastic laboratory light source exposure test method (Part 2 Xenon arc lamp)
GB/T16422.2-2014Plastic laboratory light source exposure test method (Part 2 Xenon arc lamp)
GB/T8430-98Textile Color Fastness Test, Xenon Arc Lamp for Artificial Color Fastness
GB/T1865-2009Paint, varnish, artificial air aging, and artificial radiation exposure
GB/T5137.3-96carTest method for radiation resistance, high temperature, humidity, and color aging of safety glass
GB/T2423.24-95Environmental testing for electrical and electronic products - Part 2: Test methods and testsSQSimulate solar radiation on the ground
GB/T18244-2000buildingwaterproof materialAging test method
GB/T3511-2008/ISO 4665:1998
GB/T15102-2006Impregnated film paper veneer artificial board
GB/T12831-91Rubber vulcanized artificial climate (xenon lamp) aging test method
GB/T14522-93Plastics, coatings, and rubber materials used in mechanical industry products Artificial climate acceleration test method
IIBD/SN-900Water cooled type6.5KWXenon lamp aging test chamberCabinet material
1The external gallbladder is made of high-quality materials(t=1.2mm)A3steel plateCNCProcessing and shaping, spray coating the surface of the shell for a smoother and more aesthetically pleasing appearance;
2The inner liner is imported(SUS)304High quality stainless steel plate;
3The insulation material adopts high-density glass fiber cotton and high-pressure polyurethane foam insulation;
4The mixing system adopts a long axis fan motor and a stainless steel multi blade impeller that is resistant to high and low temperatures,To achieve a strong convective vertical diffusion cycle;
5Double layer high tensile sealing strips with high temperature resistance are used between the door and the box to ensure the sealing of the testing area;
6Using non reactive door handles makes operation easier;
7The bottom of the machine adopts high-quality fixable designPUActivity wheel;
3、 Heating system:
1Using far-infrared stainless steel high-speed heating electric heater;
2High temperature, humidity, and lighting are completely independent systems (without interfering with each other);
3The output power of temperature and humidity control is calculated by a microcomputer to achieve high-precision and high-efficiency electricity efficiency;
4、 Humidification system:
1The built-in boiler steam humidifier has energy-saving and consumption reducing functions, which can save energy70%Energy consumption;
2Equipped with automatic water level compensation and water shortage alarm system;
3Humidity control is adopted for bothPID+SSRCoordinate and control the system with the same channel;
5、 Circuit control system:
1.The control instruments are imported7.0cun“Taiwan Weilun”Color touch screen programmable controller, large screen, easy operation, easy program editing, withR232Communication port, set display box temperature, box humidity, blackboard temperature, and irradiance;
2.Accuracy:0.1℃(Display Range);
3.Resolution:±0.1℃;
4.Temperature sensor:PT100Platinum resistance thermometer;
5.Control mode: thermal balance temperature and humidity control mode;
6.Temperature and humidity control adoptsP . I . D+SSRCoordinate and control the system with the same channel;
7.It has the function of automatic calculation, which can immediately correct the temperature and humidity change conditions, making temperature and humidity control more accurate and stable;
8.The controller operation interface is available in both Chinese and English, and the real-time operation curve can be displayed on the screen;
9.have100Group program, each group100Segments, each segment can be looped999The capacity of the steps is set to a maximum value of at each time interval99hour59Divide;
10.After inputting the data and experimental conditions, the controller has a screen lock function to avoid manual touch and shutdown;
11.haveRS-232perhapsRS-485Communication interface, which can be programmed on a computer to monitor the testing process and perform functions such as automatic power on/off, curve printing, and data processing;
12.The controller has an automatic screen saver function, which better protects the LCD screen (prolonging its lifespan) during long-term operation;
13.Accurate and stable control, long-term operation without drift;
14.1s ~999h、m、SThe spray stop time can be set arbitrarily;
15.The instrument displays four screens: box temperature, box humidity, light intensity, and blackboard temperature;
16.equipUVA340Or a full spectrum installation type radiometer, which can detect irradiance in real time;
17.The independent control time and alternating cycle control program and time for lighting, condensation, and spraying can be set arbitrarily;
18.In operation or setting, if an error occurs, a warning signal will be provided; France“schneider”Electrical components;
VIBD/SN-900Water cooled type6.5KWXenon lamp aging test chamberRefrigeration and dehumidification system control:
1Compressor: Fully enclosed French Taikang;
2Refrigeration method: stacked single machine refrigeration;
3Condensation method: air-cooled;
4Refrigerant:R404A(Environmentally friendly)
5All system pipelines are ventilated and pressurized48HLeak detection test;
6The heating and cooling systems are completely independent;
7Internal spiral refrigerant copper tube;
8Fin slope evaporator (with automatic defrosting system)
9The dry filter, refrigerant flow window, repair valve, oil separator, solenoid valve, and storage tank are all imported original parts;
10Dehumidification system: Adopting evaporator coil dew point temperature laminar contact dehumidification method;
7、 Lighting system:
1Blackboard thermometer: metal blackboard thermometer;
2Xenon lamp tube: water-cooled lamp tube that has passed the inspection,The lifespan of the lamp tube is600-800Hour;
3Control of irradiance: The required irradiance can be obtained by using a radiometer and manually adjusting the power,The panel directly displays the current radiation intensity of the lamp tube;
8、 Spray water circulation system:
1Water quality: Deionized water (solid content less than)20ppm)
2Equipped with a water level display for the storage tank;
3The sprayed water has recyclability;
4The water spray pressure is0.12~0.15MpaAdjustable between;
5Two nozzles were installed at the top of the studio;
BD/SN-900Water cooled type6.5KWXenon lamp aging test chamberFree home delivery, and after the installation and debugging of the equipment is completed, relevant technical personnel will perform basic operations for free at the user's sitetrainingThere is no limit to the number of people