Automatic door infrared sensor model: TAS501
When the TAS501 automatic door sensor detects someone entering, it sends a pulse signal to the main controller. After judgment, the main controller notifies the motor to run and monitors the motor speed to notify the motor to apply force and enter slow running at a certain time. After obtaining a certain operating current, the motor runs forward and transmits power to the synchronous belt, which then transmits power to the lifting system to open the door leaf; After the door leaf is opened, the controller makes a judgment. If the door needs to be closed, it notifies the motor to move in the opposite direction and close the door leaf.
Parameter Introduction
1. Installation height below 2.5m
2. Longitudinal detection range: Full beam 12 ° -20 °, sub beam 3.5 ° -1.5 ° (5 segments)
3. Power consumption below 3.0VA
4. Power supply voltage 24VAC
5. Environmental temperature -25 ° C to+55 ° C, humidity below 95%
6. Alarm output capacity DC50V, 0.5A (impedance load)
7. Pulse counting 1, 2, 3, and 4 pulses can be adjusted
8. Preheating time is about 40 seconds
9. Output duration 1.5 seconds ± 0.5 seconds
10. Sensitivity adjustment is made by adjusting the sensitivity knob