Product Introduction:
Apollo is a highly competitive fully automatic coordinate measuring machine. The Rational DMIS measurement software with powerful configuration features is intuitive, intelligent, and efficient, with rich measurement modules, strong editability, and compatibility, fully meeting personalized measurement needs.
Widely used in various industrial metrology applications such as automotive parts industry, injection molding and mold industry, 3C electronics industry, cutting and tool industry, precision machining industry, including product inspection and fixture inspection.
Product features:
Pneumatic balance: The Z-axis adopts adjustable pneumatic balance, which ensures smooth movement and automatic braking to ensure safety.
Workbench: The thick and stable overall granite workbench reduces the impact of vibration.
Structure: The movable bridge structure provides a more open measurement space.
● Guide rail: The integrated dovetail guide rail improves the operational accuracy of the entire machine.
Precision triangular beam design: Improve the rigidity of the machine and reduce the center of gravity of the crossbeam, improving the accuracy and repeatability of the machine.
All aluminum frame design: capable of consistent deformation of all parts during temperature changes, facilitating compensation.
Remote placement of drive motor: reduces moving mass, improves speed, and avoids the impact of motor heating on machine performance.
Module rich measurement software: Rational DMIS
Obtained ANSI, ISO, GB, and PTB standard certifications, fully supporting the internationally popular I++control protocol. A friendly and concise software interface, unique drag and drop quick operation, seamless connection with CAD data, and 100% graphical visualization from measurement to output reports provide enterprises with a complete measurement solution.
Rational DMIS software integrates CAD modules, thin-walled component modules, and scanning modules to meet the growing measurement needs of customers.
The features of Rational DMIS include:
100% DMIS core; Can import/export DMIS programs;
Seamless connection with CAD data;
Supports formats such as IGES, STEP, DXF, STL, XYZ, etc;
Support outputting data in formats such as Q-DAS and DML;
● Supports CATIA, UG, PRO-E, Solidworks, Parasolid direct reading interfaces;
Intelligent detection: Real time simulation of detection paths, automatic optimization of detection paths;
Complete and fast tolerance calculation: compliant with multiple standards including GB, ISO, Y14.5, ANSI, DIN, and AGMA;
Rich and diverse report outputs; Supports HTML, Excel, PDF, OUT, TXT formats.
Apollo 564/686/8xx6 performance indicators
model
|
maximum permissible errorMPE(μm),L(mm),(ISO10360-2) |
3D maximum velocity(mm/s) |
3D maximum acceleration(mm/s² ) |
HH-MI |
HP-TMe |
HP-THDe |
MPEE |
MPEP |
MPEE |
MPEP |
MPEE |
MPEP |
Apollo 564 |
2.8+L/300 |
3.1 |
2.6+L/300 |
2.9 |
2.4+L/300 |
2.7 |
520 |
1730 |
Apollo686 |
2.8+L/300 |
3.1 |
2.6+L/300 |
2.9 |
2.4+L/300 |
2.7 |
520 |
1730 |
Apollo 8106 |
3.0+L/300 |
3.2 |
2.8+L/300 |
3.0 |
2.6+L/300 |
2.8 |
520 |
1470 |
Apollo 8126 |
3.0+L/300 |
3.2 |
2.8+L/300 |
3.0 |
2.6+L/300 |
2.8 |
520 |
1470 |
Apollo 8156 |
3.0+L/300 |
3.2 |
2.8+L/300 |
3.0 |
2.6+L/300 |
2.8 |
520 |
1470 |
Probe configuration during performance testing:
HH-MI: Probe length 21mm, needle tip diameter 4mm;
HP TMe/HP THDe: standard force measurement, probe length 10mm, tip diameter 4mm.
The performance indicators are effective under the following conditions:
Standard ambient temperature:18 - 22°C
Environmental temperature changes:1°C/h - 2°C/24h
Temperature gradient:1°C/m
Relative humidity:25% - 75%
|
Size, travel range, weight

model
|
Travel Range(mm) |
External dimensions(mm) |
measurement space(mm) |
Maximum weight of the tested workpiece(Kg) |
Machine weight(Kg) |
X |
Y |
Z |
Lx |
Ly |
Lz |
Dx |
Dz |
Dz1 |
Apollo 564 |
500 |
600 |
400 |
1055 |
1535 |
2247 |
634 |
114 |
594 |
300 |
590 |
Apollo686 |
600 |
800 |
600 |
1150 |
1735 |
2630 |
734 |
114 |
794 |
300 |
730 |
Apollo 8106 |
800 |
1000 |
600 |
1350 |
1935 |
2640 |
934 |
114 |
794 |
500 |
1074 |
Apollo 8126 |
800 |
1200 |
600 |
1350 |
2135 |
2640 |
934 |
114 |
794 |
500 |
1196 |
Apollo 8156 |
800 |
1500 |
600 |
1350 |
2435 |
2640 |
934 |
114 |
794 |
500 |
1379 |
Apollo 10xx8 performance indicators
model
|
maximum permissible errorMPE(μm),L(mm),(ISO10360-2) |
3D maximum velocity(mm/s) |
3D maximum acceleration(mm/s² ) |
HH-MI |
HP-TMe |
HP-THDe |
MPEE |
MPEP |
MPEE |
MPEP |
MPEE |
MPEP |
Apollo10128 |
3.2+L/300 |
3.4 |
3.0+L/300 |
3.2 |
2.8+L/300 |
3.0 |
520 |
1470 |
Apollo10158 |
3.2+L/300 |
3.4 |
3.0+L/300 |
3.2 |
2.8+L/300 |
3.0 |
520 |
1470 |
Apollo10218 |
3.2+L/300 |
3.4 |
3.0+L/300 |
3.2 |
2.8+L/300 |
3.0 |
520 |
1470 |
Apollo10308 |
3.2+L/300 |
3.4 |
3.0+L/300 |
3.2 |
2.8+L/300 |
3.0 |
520 |
1470 |
Probe configuration during performance testing:
HH-MI: Probe length 21mm, needle tip diameter 4mm;
HP TMe/HP THDe: standard force measurement, probe length 10mm, tip diameter 4mm.
The performance indicators are effective under the following conditions:
Standard ambient temperature:18 - 22°C;
Environmental temperature changes:1°C/h - 2°C/24h;
Temperature gradient:1°C/m;
Relative humidity:25% - 75%
|
Size, travel range, weight

model
|
Travel Range(mm) |
External dimensions(mm) |
measurement space(mm) |
Maximum weight of the tested workpiece(Kg) |
Machine weight(Kg) |
X |
Y |
Z |
Lx |
Ly |
Lz |
Dx |
Dz |
Dz1 |
Apollo10128 |
1000 |
1200 |
800 |
1615 |
2220 |
2940 |
1130 |
118 |
940 |
1300 |
1785 |
Apollo10158 |
1000 |
1500 |
800 |
1615 |
2520 |
2940 |
1130 |
118 |
940 |
1500 |
2090 |
Apollo10218 |
1000 |
2100 |
800 |
1615 |
3120 |
2950 |
1130 |
118 |
940 |
1800 |
2625 |
Apollo10308 |
1000 |
2980 |
800 |
1615 |
4020 |
3010 |
1130 |
118 |
940 |
2000 |
4400 |
Apollo 12xx10/15xx10/15xx12 performance indicators
model
|
maximum permissible errorMPE(μm),L(mm),(ISO10360-2) |
3D maximum velocity(mm/s) |
3D maximum acceleration(mm/s² ) |
HH-MI |
HP-TMe |
MPEE |
MPEP |
MPEE |
MPEP |
Apollo121510 |
3.3+L/300 |
3.8 |
3.1+L/300 |
3.6 |
433 |
1040 |
Apollo122210 |
3.3+L/300 |
3.8 |
3.1+L/300 |
3.6 |
433 |
1040 |
Apollo 123010 |
3.3+L/300 |
3.8 |
3.1+L/300 |
3.6 |
433 |
1040 |
Apollo152210 |
3.8+L/300 |
4.3 |
3.6+L/300 |
4.1 |
433 |
1040 |
Apollo153010 |
3.8+L/300 |
4.3 |
3.6+L/300 |
4.1 |
433 |
1040 |
Apollo152212 |
4.3+L/300 |
4.8 |
4.1+L/300 |
4.6 |
433 |
1040 |
Apollo153012 |
4.3+L/300 |
4.8 |
4.1+L/300 |
4.6 |
433 |
1040 |
Probe configuration during performance testing:
HH-MI: Probe length 21mm, needle tip diameter 4mm;
HP TMe/HP THDe: standard force measurement, probe length 10mm, tip diameter 4mm.
The performance indicators are effective under the following conditions:
Standard ambient temperature: 18-22 ° C;
Environmental temperature variation: 1 ° C/h -2 ° C/24h;
Temperature gradient: 1 ° C/m;
Relative humidity: 25% -75%
|
Size, travel range, weight

model
|
Travel Range(mm) |
External dimensions(mm) |
measurement space(mm) |
Maximum weight of the tested workpiece(Kg) |
Machine weight(Kg) |
X |
Y |
Z |
Lx |
Ly |
Lz |
Dx |
Dz |
Dz1 |
Apollo121510 |
1200 |
1500 |
1000 |
1840 |
2895 |
3360 |
1339 |
150 |
1173 |
1800 |
3792 |
Apollo122210 |
1200 |
2200 |
1000 |
1840 |
3595 |
3410 |
1339 |
150 |
1173 |
2250 |
5696 |
Apollo 123010 |
1200 |
3000 |
1000 |
1840 |
4395 |
3440 |
1339 |
150 |
1173 |
2250 |
7637 |
Apollo152210 |
1500 |
2200 |
1000 |
2140 |
3595 |
3410 |
1639 |
150 |
1173 |
2250 |
6730 |
Apollo153010 |
1500 |
3000 |
1000 |
2140 |
4395 |
3440 |
1639 |
150 |
1173 |
2250 |
9046 |
Apollo152212 |
1500 |
2200 |
1200 |
2140 |
3595 |
3810 |
1639 |
150 |
1373 |
2250 |
6760 |
Apollo153012 |
1500 |
3000 |
1200 |
2140 |
4395 |
3840 |
1639 |
150 |
1373 |
2250 |
9076 |
Detection system:
HH-MI manual indexing measuring seat
Two directional degrees of freedom repeatable indexing measuring seat with built-in high-precision trigger probe. Each axis rotates at 15 ° intervals, allowing for positioning at 168 positions in the measurement space without the need for recalibration. The angle information can be read clearly, and the division between positions is very easy. It can be operated with one hand and has visual feedback signals to help the operator determine whether the measuring head can perform measurements.
Positioning repeatability |
1.5µm |
Dividing angle |
15° |
Division range |
A=0°-90° B=±180° |
measurement direction |
±X ±Y +Z |
Adjustable tactile force |
0.1N-0.3N |
Portable probe length |
maximum100mm |
HH-MI-M manual indexing measuring seat
The performance indicators of HH-MI-M are similar to HH-MI, but it is not an integrated measuring system. It comes with an adapter that is compatible with any matching measuring head.
Positioning repeatability |
1.5µm |
Dividing angle |
15° |
Total number of measurement positions |
168 |
Division range |
A=0°-90° B=±180° |
Longest extension rod |
50mm |
HH-A-M7.5 automatic rotating measuring seat
Automatic measuring seat, with division in increments of 7.5 °, rotation from+180 ° to -180 °, pitch from 0 ° to 105 °, and including a "leveling table" 90 ° horizontal position due to the asymmetry of the division seat. This measuring seat can quickly index, which is faster than similar products. The structure is sturdy, capable of carrying extension rods exceeding 300mm, and supports multiple trigger probes.
Positioning repeatability |
0.5µm |
Dividing angle |
7.5° |
Total number of measurement positions |
720 |
Division range |
A=0°-105° B=±180° |
rotational speed |
90°/2second |
Longest extension rod |
300mm |