Yanggu Xinyu Electronic Technology Co., Ltd
Home>Products>Analog data collector XYS-040442
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18963538740
  • Address
    Xinyu Electronic Technology Co., Ltd., Shizilou North Road, Shizilou Street, Yanggu County, Shandong Province
Contact Now
Analog data collector XYS-040442
XYS-040442 is an intelligent module that integrates switch output, analog output, analog acquisition, and switch input acquisition. The computer sends
Product details

XYS-040442User Manual for Simulated Data Acquisition Module

1 function

XYS-040442It is an intelligent module that integrates switch output, analog output, analog acquisition, and switch input acquisition. The computer sends instructions to the data acquisition module through the serial port to control or read commands. After receiving the commands, the controller executes single relay actions, multiple relay actions, relay fully open, relay switch, switch input status acquisition, analog acquisition, and analog output.

1. Communication isolation, using ultra high speed magnetic coupling chips to meet high baud rate communication requirements;

2. 12Vperhaps24VDC voltage power input, anti reverse protection.

3. Rich status indicator lights, including relay output status indicator lights, switch input status indicator lights, communication indicator lights, and power indicator lights;

4. Having standardRS232/RS485Waiting for the communication port,TCPIP /Bluetooth/wireless/wifi/GPRSOptional.

5. Built in alarm buzzer, which can remotely control alarms or provide on-site prompts, achieving sound and light alarms;

6. supportmodbus RTUProtocol customization or hardware customization, suitable for allPLCConnection of modules;

7. Adopting a guide rail typeABSShell, can be installed inside the cabinet or wall mounted;

II Technical Parameter

1. Working power supply:DC12VperhapsDC24VPower consumption: less than5W

2. Communication port:RS232/RS485/networkTCPIPBaud rate:4800/9600/19200bps/38400

3. Communication distance:RS232 15Mi,RS485 1000Meter, Ethernet100MWiFi/Bluetooth 20Rice;

4. Communication protocol:modbus RTUOr customized agreements with customers;

5. Work environment:-25-65℃, humidity5-95%

6. relay:4road Load capacity:220V AC 5A; Normally open output;

7. Switch input:4Road, dry node or optocoupler, closing resistance less than100ohm,Open circuit resistance greater than100K

8. Analog input:4roadAIinput range0-10Vperhaps0-20mA/4-20mAOther customization; resolution12Position;0-4096

9. Analog input assistance:2roadAOOutput range0-10Vperhaps0-20mA/4-20mAOther customization; resolution12Position;0-4096

10. zero drift:±0.2uA/℃ or zero drift:±0.2uV/℃;;

11. buzzer1One;

12. Rail typeABShousing 145LX 90(W)X 40(H)mm(Internal)PCBBoard size:88*120*30mm;)

output

Output range

Resolution

accuracy

describe

electric current

0.00~20.00mA

0.05mA

±0.1mA

0-4000 20mAMaximum Load500Ω

voltage

0.00~-10.00V

0.025V

±0.1 V

0-4000maximum output current100mA

III communication protocol

supportMODBUS-RTUfunction code01020405060FFunction code. The default communication baud rate is9600Invalid verification8Data bits1A stop position.

function code

purpose

read/write

give an example

notes

01

Relay status reading

read

TX:01 01 00 00 00 10 3D C6

RX01 01 02 02 00 B8 9C

read16Relay status, taken before4position

02

Switch input reading

read

Tx:01 02 00 00 00 10 79 C6

Rx:01 02 02 08 00 BE 78

read16Relay status, taken before4position

04

Analog reading, switch quantity

read

Tx01 04 00 00 00 14 F0 05

RX: 01 04 28 03 E8 00 00 00 32 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 99 3D

read2Simulate input values,4Analog input value, baud rate, address, switch input, switch output

05

Relay single control

write

close:01 05 00 00 FF 00 8C 3A

to break off:01 05 00 00 00 00 CD CA

The first way to open and close

06

analog output

write

Tx:01 06 00 00 07 D0 8A 66

Rx:01 86 01 83 A0

analog quantity1write1000

0F

Multiple controls for relays

write

Tx:01 0F 00 00 00 10 02 15 00 EC B0

Rx:01 8F 01 85 F0

relay135 close

l Write single register--06

for example1Channel of the number device1The analog output of, that is, the write register4x0000The command is as follows:

MODBUSRegister Address Table1

Register address

Number of registers

Variable

Register type

describe

4x 0000

1

OUT1output

read/write

Company:0.01milliampere

Company:0.01volt

4x 0001

1

OUT2output

read/write

4x 0002

1

IN1Input quantity

read only

For example, reading the value is800

Indicates that the read voltage value is8V

4x 0003

1

IN2Input quantity

read only

4x 0004

1

IN3Input quantity

read only

4x 0005

1

IN4Input quantity

read only

4x 0006

1

reserve

read only

4x 0007

1

reserve

read only

4x 0008

1

reserve

read only

4x 0009

1

reserve

read only

4x 0010

1

Baud rate

read/write

Refer to the code table2

4x 0011

1

Address setting

read/write

0-250

4x 0012

1

Switching input1

read only

4x 0013

1

Switching input2

read only

4x 0014

1

Switching input3

read only

4x 0015

1

Switching input4

read only

4x 0016

1

relay status1

read/write

4x 0017

1

relay status2

read/write

4x 0018

1

relay status3

read/write

4x 0019

1

relay status4

read/write

4x 0020

1

not have

Baud rate code table2

numerical value

1

2

3

4

5default

6

7

8

9

Baud rate

300

1200

2400

4800

9600

19200

38400

57600

115200

port name

Connect content

port name

Connect content

P+

Module power supply positive pole

AO1

Analog Output1

P-

Module power supply negative pole

Switching input ground

AO2

Analog Output2

X1

Switching input1

GND

Analog input ground

X2

Switching input2

AIN1

analog input1

X3

Switching input3

AIN2

analog input2

X4

Switching input4

AIN3

analog input3

N

Empty, no connection

AIN4

analog input4

D-

RX485negative terminalB-

N

Empty, no connection

D+

RX485Positive endA+

Y1 C1

relay1normally open

RXD

RX232receiving end

Y2 C2

relay2normally open

TXD

RX232Sender

Y3 C3

relay3normally open

GND

RX232grounds

Y4 C4

relay4normally open

Determine whether it is current or voltage input/output before purchasing the module

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!