Yangzhou Aikered Instrument Co., Ltd
Home>Products>Aikered AKD-K5 Micro Moisture Analyzer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18112147087
  • Address
    No.1 Xincheng Road, Daqiao Industrial Park, Jiangdu District, Yangzhou City
Contact Now
Aikered AKD-K5 Micro Moisture Analyzer
The AKD-K5 micro moisture analyzer from Aikered brand uses the Karl Fischer coulomb method, which is a globally recognized method for testing water co
Product details

艾科瑞德AKD-A9全自动微量水分测定仪(图1)

正面.jpg

艾科瑞德AKD-A9全自动微量水分测定仪(图3)

Acored brandThe AKD-K5 micro moisture analyzer uses the Karl Fischer Coulombic method, which is a globally recognized method for testing water content. The instrument adopts an LCD color 7-inch large screen display, touch screen operation, and intelligent human-computer interaction interface. The powerful new generation processor with dual CPU design greatly improves computational efficiency. The design of dual power channels separates the electrolytic electrode from the measuring electrode, and the instrument can automatically remove various interferences. The resolution of 0.1ug water greatly improves the precision of test results, reaching 0.001ppm. Built in multiple calculation formulas to meet the testing needs of different samples, capable of storing 1000 sets of experimental data, and equipped with an embedded printer to directly print out experimental data.

Acored brandThe AKD-K5 trace moisture analyzer has the advantages of high measurement accuracy, good repeatability, and low testing cost. It is widely used in departments such as petroleum, chemical, pharmaceutical, power, scientific research, and education, and can be used to measure trace moisture in various liquids, solids, and gases.

艾科瑞德AKD-A9全自动微量水分测定仪(图4)

Acored brandAKD-K5 Trace Moisture AnalyzerTechnical parameters:

model: AKD-K5
Measurement method: Karl Fischer Coulomb coulometric method
Display measurement range: 0.1ug water -9999.9999mg water
Water content range: 0.0001% -100% or 0.001ppm106ppm
resolving power: 0.1ug water
Display mode: LCD color 7-inch large screen display
Accuracy: When the water content is between 3ug and 1000ug, the measurement error is ≤± 2ug
When the water content is above 1000ug, the measurement error≤±0.2% (excluding injection error)
Endpoint indication: Screen display/sound warning/print output/endpoint light prompt
Blank processing: The blank current microprocessor automatically controls compensation to ensure accurate deduction of blank during the 10 minute sample enrichment time
Mixing speed: Adjustable control
Drift compensation: Microprocessor automatic control
Data input: Touch screen
Sample Number: User
Electrolysis speed: 2.4 mg water/min
Electrolytic current: 0-430mA
Data storage: 1000 items
Printing function: Built in thermal printer, 56mm paper width
Print content: Ug/ppm/mg/L/sample number/experimenter/date
External functions: Can connect to a computer and work both online and independently
Self checking function: Automatic diagnosis of instrument faults
Calendar/Clock: Analyze time and date display and print output (without losing power)
External dimensions: 350*260*198mm
Power consumption: Less than 100W
Using power supply: Voltage 220V±10% frequency 50Hz±2.5HZ
Usage environment: Temperature 5-40 ℃, humidity<85%
Weight: About 6KG
Optional features: Optional automatic liquid addition and discharge function

艾科瑞德AKD-A9全自动微量水分测定仪(图5)

Acored brandAKD-K5 Trace Moisture AnalyzerScope of application:

liquid Pharmaceutical industry: raw materials for traditional Chinese and Western medicine, etc
Pesticide industry: emulsification, etc
Petroleum and power industry: insulation oil, transformer oil, etc
Chemical industry: acids, alcohols, benzenes, phenols, ethers, organic solvents, etc
Other industries: lithium batteries, electrolytes, etc
solid Solid substances with good solubility, such as various inorganic salts and citric acid
gas Natural gas, liquefied gas, fluorocarbons, butadiene and other gases

艾科瑞德AKD-A9全自动微量水分测定仪(图6)

Acored brandAKD-K5 Trace Moisture AnalyzerCompliant with standards:

GB/T 6283-2008 Determination of Moisture Content in Chemical Products (Karl Fischer Method)
ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids
GB/T 7600-1987 Determination of Moisture Content in Operating Transformer Oil (Coulombic Method)
ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
ASTM D6304-2007 Karl Fischer coulometric titration method for determining water content in petroleum products, lubricants, and additives
ISO 10337-1997 Determination of Moisture in Crude Oil (Karl Fischer Coulombic Titration Method)
GB/T 11146-2009 Determination of Crude Oil Water Content (Karl Fischer Coulombic Titration Method)
GB/T 3727-2003 Determination of Trace Water in Ethylene and Propylene for Industrial Use
GB/T 5074-1985 Method for determination of moisture content in coking products by microcoulometry
GB/T 6023-2008 Determination of Trace Water in Industrial Butadiene (Karl Fischer Coulombic Method)
GB/T 7376-2008 Determination of Trace Moisture in Fluoroalkanes for Industrial Use (Karl Fischer Method)
GB/T 18619.1-2002 Determination of Water Content in Natural Gas (Karl Fischer Coulombic Method)
GB/T 18826-2002 Industrial 1,1,1,2-tetrafluoroethane HFC-134a
SH/T 0246-1992 Determination of Water Content in Light Petroleum Products (Electricity Method)
SH/T 0255-1992 Method for determination of moisture content in additives and lubricating oils containing additives (electric method)
ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids
ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
ASTM D6304-2007 Standard for Determination of Water Content in Petroleum Products, Lubricants, and Additives by Karl Fischer Coulombic Titration

艾科瑞德AKD-A9全自动微量水分测定仪(图7)

Acored brandAKD-K5 Trace Moisture AnalyzerHas the following characteristics:
1. 7-inch color touch LCD screen display, efficient microprocessor, real-time display of instrument working status;
2. The instrument screen displays time and status trend curves, which more intuitively reflect changes in moisture content;
3. Adopting a composite control system of microcontroller and computer, dual CPU design, intelligent analysis and determination of moisture content;
4. The dual power channel separates the electrolytic electrode from the measuring electrode, and the instrument can automatically suppress various interferences, greatly improving the precision of the test results;
5. Built in multiple calculation formulas, users can choose the appropriate testing method, and the instrument will automatically calculate the water score based on the selected formula;
6. The instrument comes with a built-in delayed titration function, which can set a countdown of 0-100 seconds, making it convenient to install a Karl Fischer headspace sampler or a blow and fill instrument in the later stage, with higher cost-effectiveness;
7. Automatically calculate and print ug/ppm/percentage content/mg/L/sample name/experimental date, etc;
8. The instrument automatically stores data and can store 1000 sets of data for easy access to historical records;
9. The blank current microprocessor automatically controls compensation, and the reagent can quickly reach equilibrium state;
10. The instrument has a self checking function. If there is a short circuit or open circuit fault in the electrode, the instrument will automatically prompt the user;
11. 0-430mA high electrolysis current, high detection sensitivity and fast analysis speed;
12. The surface of the body is treated with electrostatic spraying, which is corrosion-resistant and easy to clean;
13. The perpetual calendar function includes year, month, day, week, hour, minute, and second, which are automatically stored after power failure and will not be lost for 10 years.

艾科瑞德AKD-A9全自动微量水分测定仪(图8)

Acored brandAKD-K5 Trace Moisture AnalyzerOperation steps:
1. After installing the instrument accessories according to the instructions, turn on the instrument;
2. Set parameters according to the instructions, select different setting items, and press the confirm button to save after selection;
3. Reagent equilibrium. Inject an appropriate amount of pure water into a 50 microliter sampler to neutralize any excess water in the reagent;
4. Instrument calibration. Using a 0.5ul sampler to extract 0.1ul of pure water for injection, the displayed result should be 100 ± 10ug (excluding injection error). If the displayed result is within the error range, sample measurement can be performed.
5. Sample determination. After pressing the start button to inject the sample, the instrument will automatically perform the test. After the test is completed, a beep alarm will sound and the display screen will indicate "Test completed".

艾科瑞德AKD-A9全自动微量水分测定仪(图9)

Acored brandAKD-K5 Trace Moisture Analyzermatters needing attention:

1、 Cannot display normally
Please check if the power connection wire, fuse, and power switch of the instrument are functioning properly.
2、 The instrument displays iodine
1. Evaluate whether the reagent is over iodine. If so, use a 0.5 microliter sampler to extract 0.2-0.4 microliters of water and inject it. Do not use an injector of 50 microliters or larger for injection.
2. Check whether the platinum wire at the bottom of the measuring electrode is connected together, causing a short circuit.
3、 The instrument shows an open circuit
Check if the measuring electrode is in good contact and re insert it firmly. Check if the connecting wire is broken.
4、 Open electrolysis without counting
Check if the electrolytic electrode is in good contact, unplug and plug it again, and check if the connecting wire is broken.
5、 Electrolysis does not end
Check if the reagent has expired.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!