1WX88-PHLadjusted typebalanceflowmeterIntroduction:
WX88-PHLadjusted typebalanceflowmeter(Also known as porous orifice plateflowmeter)According to the national standardGB2624A new type of throttling flow sensor developed based on standard orifice plates and flow regulators. Adjustable orifice plates are used for installation downstream of various disturbances and vibrations, providing excellent performance in the shortest straight pipe section.adjusted typebalanceflowmeterThe traditional throttling device has been greatly improved, and the flowmeter has significant features such as balanced rectification. The traditional throttling device only has one flow aperture, which causes the fluid to lose its ideal state after throttling; ButbalanceThe flowmeter has multiple functional apertures, which can Maximizing the balance and rectification of the flow field into an ideal fluid, thereby fully utilizing the advantages of differential pressure flow meters. Without moving parts, installation and use are very convenient and simple, eliminating the need for large straight pipe sections and greatly reducing fluid transport The energy consumption required for operation is an energy-saving instrument with broad application prospects.
Integrated adjustment typebalanceFlow meter composition diagram
IIWX88-PHLadjusted typebalanceflowmeterworking principle:
integrationadjusted typebalanceflowmeterIt is a revolutionary differential pressure flow instrument,It adopts an adjuster type orifice plate structure, which can be applied in situations where there are turbulent flow field factors upstream.Its working principle, like other differential pressure flow meters, is based on the energy conversion principle in a sealed pipeline: under ideal fluid conditions, the flow rate in the pipeline is proportional to the square root of the differential pressure Proportional; By measuring the differential pressure value and using the equation, the flow rate in the pipeline can be calculated. The balanced flow sensor is a porous disk throttling rectifier installed on the cross-section of the pipeline, and the size and distribution of each hole are based on a special formula Tailored to test data, it is called a function hole. When the fluid passes through the function hole of the disk, it will be balanced and rectified, the vortex will be minimized, and an approximate ideal fluid will be formed. By using a pressure measuring device, a stable differential pressure signal can be obtained, According to the laws of conservation of mass and energy in fluid mechanics, the volumetric and mass flow rates of a fluid can be calculated.
WX88-PHLadjusted typebalanceflowmeterMeasurement schematic
IIIWX88-PHLadjusted typebalanceflowmeterProduct Features
1.Revolutionary innovative technology based on most ordinary primary differential pressure components in industry
2.After upstream flow disturbance, only a length of needs to be laid2Double diameter straight pipe section
3.Reduced installation costs
4.Easy to use, inspect, and troubleshoot
5.Suitable for mostGas, liquid, gas-liquid two-phase, liquid gas, bidirectional flow, dirty medium, slurryApplication scenarios for steam and high temperature and high pressureThe measurement
6.Eliminating vortices and irregular flow profiles caused by upstream interference (double bends, valves, reducers)
7.The balanced flow sensor has the characteristics of a symmetrical porous structure, which can balance the flow field, reduce eddy currents, vibrations, and signal noise, greatly improve the stability of the flow field, and enhance the linearity compared to orifice plates5~10Twice, the repeatability has been improved54%, for0.15%.
8. Balanced flowofThe porous symmetrical balance design reduces the formation of turbulent shear forces and eddies, reduces the loss of kinetic energy, and under the same measurement conditions, compared to orifice plates, reduces2.5Twice the permanent pressure loss, thus saving considerable operating energy costs
4WX88-PHLadjusted typebalanceflowmeterComparison with standard orifice plate
1、balanceThe measurement accuracy of the flowmeter is the same as that of a standard orifice plate5~10times
2、balanceThe flow noise of the flowmeter is that of a standard orifice plate1/15
3、balanceThe permanent pressure loss of the flowmeter is that of a standard orifice plate1/3
4、balanceThe pressure recovery of the flowmeter is faster than that of the standard orifice plate2times
5、balanceThe minimum straight pipe section of the flowmeter can be smaller than0.5D
adjusted typebalanceflowmeterComparison diagram of requirements for straight pipe sections with standard orifice plates
5WX88-PHLadjusted typebalanceflowmeterMain technical parameters
1.Pipeline size:15 ≤DN≤1200 mm
2.Nominal pressure:PN≤40Mpa
3.Working temperature:-250℃≤t≤550℃
4.Range ratio:1:10,1:15
5.Accuracy level:0.5Level,1Level,1.5level
6.Reference standard:GB/T2624-2006、JJG640-94Design Manual for Flow Measurement and Throttle Devices
7.Connection method: clamp or flange connection
VIWX88-PHLadjusted typebalanceflowmeterStructural selection diagram
7WX88-PHLadjusted typebalanceflowmetermodel selection
WX88-PHL |
adjusted typebalanceflowmeter |
||||
Highway diameter |
-XXX |
100 represents DN100 |
|||
Installation form |
pp |
Pipeline type |
|||
HF |
wafer type |
||||
FW |
welded type |
||||
DF |
Double flange type |
||||
SP |
Square tube type |
||||
nominal pressure |
A |
0~0.6MPA |
|||
B |
0~1.0MPA |
||||
C |
0~1.6MPA |
||||
D |
0~2.5MPA |
||||
E |
0~4.0MPA |
||||
F |
0~6.4MPA |
||||
G |
0~10MPA |
||||
H |
0~16MPA |
||||
J |
0~40MPA |
||||
Pipe Material |
0 |
carbon steel |
|||
1 |
304 stainless steel |
||||
2 |
12CrMOV |
WX88-PHLadjusted typebalanceflowmeterPhysical picture
8WX88-PHLadjusted typebalanceflowmeterAfter sales service commitment
1If there are quality problems with the products sold by our company within twelve months, we are responsible for free repairs.
2If there are any quality problems with our company's products during the warranty period, our company is responsible for free repair or replacement.
3If the product is damaged due to improper use by the user during the warranty period, our company is responsible for repairing it and charging the cost of the damaged parts.
4After the warranty period, if there are quality problems with the product, our company is responsible for repairing and charging the cost of damaged parts.
5Our company's 24-hour hotline:/86901876/86902876/
6.If the user requires our company's on-site service, our company personnel will assist users within the province24Arrive at the scene within hours, for users outside the province72Arrive at the scene within hours.