Acored drying method halogen moisture analyzer
Drying method halogen moisture analyzer, also known as halogen moisture analyzer, is widely used in all industries that require moisture testing. This
Product details



Drying method halogen moisture meterAlso known as "halogen moisture analyzer"Widely used in all industries that require moisture testing, this moisture meter can be used to test plastics, plastic particles, chemical products and other plasticizing industries.
Acored brandDrying method halogen moisture meterIt is an instrument for rapid detection of sample moisture, using a circular halogen lamp as the heating source. By injecting halogen gases such as iodine or bromine into the infrared lamp, it undergoes a chemical reaction with the sublimated tungsten wire during high-temperature testing and re solidifies on the tungsten wire to achieve an equilibrium state, ensuring the working efficiency of the halogen lamp.
Acored brandDrying method halogen moisture meterUsing the principle of thermogravimetric analysis and relying on a high-precision weighing system, the sample weight, moisture content, and solid content are displayed in real-time during the measurement process. After drying is completed, the test results are locked and displayed. During the testing process, real-time detection of drying time, drying temperature, etc. can be carried out, and the testing curve can intuitively reflect the progress of sample testing.
Acored brand
Drying method halogen moisture meterCompared with the traditional oven method,The sample size is small, the drying time is short, and the operation is simple. Its detection results have good consistency with the national standard oven method and are replaceable.



Acored brandDrying method halogen moisture meterTechnical parameters:

model: AKD-W5 AKD-W1 AKD-W10 AKD-W10S
Sample weighing range: 0.005—120g 0.001—120g 0.0001—120g
Moisture content range: 0.01%— 100% 0.01%— 100% 0.001%— 100%
Solid content range: 100% —0.01% 100% —0.01% 100% —0.001%
Weighing accuracy: 0.005g (5 milligrams) 0.001g (1mg) 0.0001g (0.1 milligrams)
Repeatability (>10g): ±0.05% ±0.01% ±0.001%
Readability of moisture content: 0.01% 0.01% 0.001%
Calibration method: Linear calibration, external weight calibration
Sample disk size: Inner diameter 90 mm, outer diameter 102 mm
Sample disk material: Medical grade anti-interference stainless steel sample tray
Measurement program: Over 1000 industry-specific custom measurement modes
Control processor: Integrated control of three line interconnection
Baud rate: 300, 600, 1200, 2400, 4800, 9600
Response time (average): 2.5 seconds
Appearance: Integrated operation screen sensor Split type operation screen sensor
Dimensions (length * width * height): 310*205*200 mm 230*260*160 mm
The weighing sensor: Original imported gold-plated ceramic sensor from the United States
Temperature sensor: High precision PT100 platinum thermistor
monitor: Backlit LCD display 7-inch color intelligent touch display screen
Display content: Weight g, moisture content MC%, solid content DC%, time min, temperature ℃, testing progress curve
System language: Chinese chinese and english
Computer operating system: —— F1.0
Heating temperature range: Room temperature -200 ℃
Temperature testing and calibration: ­—— Temperature calibration (customizable)
Drying Procedure: Standard heating, intelligent heating, and weight loss rate heating modes
Humidity display mode: relative humidity
Shutdown mode: Intelligent shutdown, semi-automatic shutdown, temperature controlled timed shutdown
Set time: 0-99 minutes with a 1-minute interval
Communication interface: RS232 interface USP、 network port
External devices: Intelligent software can connect to devices such as printers and computers
printer: Optional thermal printer
Measurement results: Control chart, ID management, drying curve, A4/Letter printing
Using power supply: Voltage 220V ± 5% frequency 50HZ ± 1HZ
Usage environment: Suggested room temperature -40 ℃, humidity 10% -70%
Weight: About 7.8KG


Acored brandDrying method halogen moisture meterScope of application:
Drying method halogen moisture meterIt can measure solid particles, blocks, flakes, powders, non-volatile liquids, etc., suitable for all industries that require rapid measurement of moisture, such as chemical industry, textile industry, electronics and semiconductor industry, pharmaceutical industry, paper industry, tobacco, food, tea, beverages, grains, coal, plastic raw materials, sewage treatment, etc. It is a universal halogen moisture analyzer that can be used for production processes and experimental analysis.



Acored brandDrying method halogen moisture meterHas the following characteristics:
1. Widely applicable for moisture determination in various industries;
2. Eliminating installation and debugging steps, it can be used immediately after unpacking;
3. Low sampling volume, simple operation, short testing time, and improved work efficiency;
4. The heating method of the annular halogen lamp ensures a more balanced and uniform heating of the sample, ensuring the accuracy of the test results;
5. Imported gold-plated ceramic sensors from the United States, with high precision, stable performance, and long lifespan;
6. The heating chamber adopts a pure stainless steel body, which is heat-resistant and easy to clean;
7. The temperature control adopts high-precision PT100 platinum thermistor, which provides more accurate temperature;
8. Fully automatic measurement, automatic buzzer alarm reminder after measurement, no need to supervise the measurement process;
9. During the testing process, the weight, moisture content, and solid content of the sample can be switched and displayed at any time;
10. Unique windproof cover design, not affected by environmental temperature and humidity, no need for auxiliary equipment;
11. Real time display of test curve chart, observing moisture changes and testing progress at any time;
12. Multiple testing methods, including intelligent, semi-automatic, timed temperature control, etc., meet various testing needs;
13. Standard RS232 interface, convenient for connecting printers, computers, and other peripheral devices;



Acored brandDrying method halogen moisture meterOperation steps:
1. Press the reset button to reset, take a sample, and evenly spread the sample on the sample tray.
2. Close the heating chamber, press the test button, and the instrument will start working. When the instrument is heated, the current moisture value MC% is displayed on the screen, and pressing the switch button displays the current solid content DC% and the weight after drying.
3. The measurement is completed, and the instrument automatically beeps an alarm. Press the stop button to end. At this time, the instrument displays the test moisture value and switches to display the solid content rateDC%After drying, the weight is g. Press the reset button to return to the weighing mode.
4. Press the print button to send the test results to the printer. (Printer is an optional accessory)
5. After the instrument cools down to room temperature, the measurement of the next sample can be carried out.



Acored brandDrying method halogen moisture metermatters needing attention:
1. Please read the instructions carefully before use and do not use in environments that do not meet the requirements.
2. Adequate space should be ensured around the instrument to prevent heat accumulation and overheating that may affect its normal use.
3. Due to the heating unit of the instrument causing the surrounding area to heat up, do not place flammable materials around the instrument.
4. After the test is completed, the sample itself and the heating chamber will still be very hot, so caution should be taken when removing the sample to avoid burns.
5. During the heating and drying process, the temperature of the circular heating element will reach 400 ℃. Therefore, do not open or touch the heating unit. If you need to turn it on, please disconnect the power and wait until it completely cools down.
6. Samples containing toxic elements can only be heated and dried under well ventilated conditions.
7. The halogen moisture analyzer is used to measure the moisture content in samples, and any other use may cause harm to individuals and damage to the instrument.