Kunshan Iris Automation Technology Co., Ltd
Home>Products>ARSLU current type vortex flowmeter
ARSLU current type vortex flowmeter
Product Code: 012 Product Name: ARSLU Current Vortex Flow Meter Product Specification: ARSLU Current Field Display Vortex Flow Meter Product Category:
Product details

1、 Working principle

ARSLUOn site display shows that the current output type vortex flowmeter is equipped with a triangular column vortex generator in the fluid, which alternately generates two columns of regular vortices from both sides of the vortex generator. This type of vortex is called Karman vortex street

ARSLUThe vortex column of the current type vortex flowmeter is asymmetrically arranged downstream of the vortex generator. Let the frequency of vortex occurrence befThe average velocity of the incoming flow of the tested medium isVThe width of the upstream face of the vortex generator isdThe diameter of the body isDAccording to the principle of Karman vortex street, there is the following relationship:

f=St.V/[](1-1.25d/Dd[]

In the formula:

fFrequency of Karman vortex generated on one side of the body

StStrohal number

V- Average flow velocity of fluid

d- Column flow surface width

D-PIPE INNER DIAMETER

By installing capacitance detection probes or piezoelectric detection probes and corresponding matching circuits in the vortex generator, a capacitance detection vortex flow rate can be formed/Sensor or piezoelectric detection type vortex flow sensor.

In the curve tableSt0.17The frequency of vortex release is proportional to the flow velocity in the straight part of the vortex,That is, the measurement range of the vortex flow sensor. As long as the frequency is detectedfThe flow velocity of the fluid inside the pipe can be obtained by measuring the flow velocityVCalculate the volumetric flow rate.

  Q3600f/KperhapsM=ρ3600 f/K

In the formula:K=Instrument constant(1/m³)。

M=mass flow

Q=Volume flow rate(m³/h

ρ=Medium density(kg/m³)

F=frequencyHz

2、 Main technical indicators

outside(one)

Measurement medium

Liquid, gas, steam (single-phase medium or medium that can be considered single-phase)

Saturated steam with dryness ≥85%When, it can be considered as a single-phase medium

medium temperature()

-40+300 350450(Capacitive, protocol ordering)

Medium pressure

1.6Mpa 2.5Mpa 4.0Mpa 4.0MpaThe specification agreement for ordering

Allow vibration acceleration

Capacitive sensor:1.02.0g Piezoelectric sensor: ≤0.2g

Uncertainty

1.0level 1.5level 2.5level

Range ratio

8:1 10:1 15:1

Flow range

Liquid:0.35~7.0m/s Gas:5.0~60.0m/s Steam:6.0~70.0m/s

Specifications

Full tube type

The flange card installation specification isDN15-DN300

plug-in

DN200-DN1500(Exceeding)DN1500Special orders are available)

Material

304Other material agreement ordering

Reynolds number

normal2×10³~7*10 extend1*10~7*10

drag coefficient

Full tube typeCd2.6

protection grade

Ordinary type:IP65 Diving type:IP68

Explosion proof grade

Intrinsic safety type:EXia)ⅡCT2-T5 Explosion proof type:ExdBT2-T5

environmental condition

ambient temperature

-40~+55℃ (non explosion proof location) -25~+55℃ (explosion-proof location)

relative humidity

90%

atmospheric pressure

86~106kPa

power supply

impulsive12VDC+24VDC current mode12VDC+24VDC 4-20mA On Battery3.6V

output signal

Frequency pulse signal2~3000Hz Low level ≤1V High level ≥5V

two-wire system4-20mAExplosion proof signal load ≤300Ω Non explosion proof load ≤500Ω

3、 Flow Range Table of Vortex Flow Sensor under Reference Conditions

Instrument caliber

(mm)

liquid

gas

measuring range

(m3/h)

Output frequency range

(Hz)

measuring range

(m3/h)

Output frequency range

(Hz)

15

0.3-6

88-580

2.2-38

240-2350

20

0.6-12

38-422

4-50

210-2132

25

1.216

25336

8.855

1901140

40

240

10200

27205

1401040

50

360

8160

35380

941020

80

6.5130

4.182

861100

55690

100

15220

4.769

1331700

42536

150

30450

2.843

3474000

33380

200

45800

231

5608000

22315

250

651250

1.525

89011000

18221

300

952000

1.224

136018000

16213

(300)

1001500

5.587

156015600

85880

(400)

1803000

5.687

275027000

85880

(500)

3004500

5.688

430043000

85880

(600)

4506500

5.789

610061000

85880

(800)

75010000

5.788

11000110000

85880

(1000)

12001700

5.888

17000170000

85880

>(1000)

agreement

agreement

Note: In the table(300)(1000)The caliber is insertable

4、 Standard state density of commonly used gas media(20Absolute pressureP=0.1MPa

Gas name

density(kg/m3)

Gas name

density(kg/m3)

air(shield)

1.2928

acetylene

1.1717

nitrogen

1.2506

ethylene

1.2604

oxygen

1.4289

propylene

1.9140

argon

1.7840

methane

0.7167

neon

0.9000

ethane

1.3567

ammonia

0.7710

propane

2.0050

hydrogen

0.08988

butane

2.7030

carbon monoxide

1.97704

natural gas

0.8280

carbon dioxide

1.3401

coal-to-gas

0.8020

5、 Selection of vortex flowmeter:

Specification code

describe

enterprise standard

ARS

Instrument type

L

FLOW METER

Working principle

U

Carmen Vortex Street

Product category

B

Common

C

Fixed insertion type

G

local display

Installation type

-2

Flange card installation

Tested fluid

2

liquid

3

gas

Path code

-01B

orifice15mm

02A

orifice20mm

02

orifice25mm

03

orifice32mm

04

orifice40mm

05

orifice50mm

06

orifice65mm

08

orifice80mm

10

orifice100mm

12

orifice125mm

15

orifice150mm

20

orifice200mm

25

orifice250mm

30

orifice300mm

35

orifice350mm

40

orifice400mm

45

orifice450mm

50

orifice500mm

XX(Only plug-in type)

orificeXX*10mm

Table body material

C

carbon steel

F

stainless steel

Converter type

-1

combined type

output signal

1

Pulse frequency output

2

0-10mAoutput

3

4-12mAoutput

Fluid temperature

1

Common-40+250oC

3

High temperature type+250oC+350oC

Online inquiry