The AMR-C9E series intelligent digital electric meter has precise power parameter measurement, four quadrant energy metering, over limit alarm, and maximum value recordingLED high brightness digital displayOther functions; Through the extended I/O module, powerful monitoring functions can be achieved for monitoring and controlling the status of on-site equipment. It integrates industrial standard communication interfaces and multiple extended communication modules, making it easy to integrate with various intelligent distribution systems; It can be directly used as a server in the Internet to publish real-time monitoring data for authorized users through web browsing, or report the monitoring data and status to users by sending emails on a regular basis or triggered by status. Multiple wiring methods, easy to use, can adapt to various requirements on site. And after power failure, the set parameters will not be lost.
application area
The AMR-C9E series intelligent digital electricity meter can be applied to data acquisition units in intelligent distribution systems or power automation systems.
The main application areas are:
■ Medium and low voltage distribution system ■ Intelligent switch panel cabinet
■ Factory automation system ■ Industrial machinery and equipment
■ Energy Management System ■ Intelligent Building
basic function
The AMR-C9E series intelligent digital electric meter has a complete power parameter measurement function, providing real-time measurement of the following data:
Voltage V: three-phase phase voltage, line voltage, and their average values
■ Current I: three-phase line current and its average value, neutral line current
■ Active power P: active power of each phase in the four quadrants and active power of the system
Reactive power Q: Reactive power of each phase in the four quadrants and reactive power of the system. The calculation method for reactive power can be selected; Generalized reactive power or narrow reactive power
■ Apparent power S: apparent power of each phase and apparent power of the system
Power factor PF: power factor of each phase and system power factor
Frequency F: When a voltage signal is present, the frequency of the system can be measured
Quick selection table for three-phase intelligent digital electric meters
Quick selection table for intelligent digital electric meters | ||||
Function Description | LED display model | LCD display model | Application scenarios | notes |
3I | AMR-C9E1 | AMR-C9C1 | Three types of circuits including power box for outgoing lines | No communication |
3U | AMR-C9E2 | AMR-C9C2 | Three types of circuits including power box for outgoing lines | No communication |
3I、3U | AMR-C9E3 | AMR-C9C3 | Three types of circuits including power box for outgoing lines | No communication |
3I、3U、Ep、Eq | AMR-C9E7 | AMR-C9C7 | Three types of circuits including power box for outgoing lines | No communication |
3I、RS485 | AMR-C9E1M | AMR-C9C1M | Outgoing circuit | Communication and telemetry are available |
3U、RS485 | AMR-C9E2M | AMR-C9C2M | Outgoing circuit | Communication and telemetry are available |
3I、3U、RS485 | AMR-C9E3M | AMR-C9C3M | Outgoing circuit | Communication and telemetry are available |
3I、3U、Ep、Eq、RS485 | AMR-C9E7M | AMR-C9C7M | Outgoing circuit | Communication and telemetry are available |
3I、3U、P、Q、S、PF、Ep、Eq、RS485 | AMR-C9E9M | AMR-C9C9M | Incoming and outgoing circuit | Communication and telemetry are available |
3I、3U、P、Q、S、PF、Ep、Eq、H、RS485 | not have | AMR-C9C9MH | Incoming and outgoing circuit | There are communication, telemetry, and harmonics |
3I、RS485、2DI | AMR-C9E1M1 | AMR-C9C1M1 | Outgoing circuit | There are communication, telemetry, and remote signaling |
3U、RS485、2DI | AMR-C9E2M1 | AMR-C9C2M1 | Outgoing circuit | There are communication, telemetry, and remote signaling |
3I、3U、RS485、2DI | AMR-C9E3M1 | AMR-C9C3M1 | Outgoing circuit | There are communication, telemetry, and remote signaling |
3I、3U、Ep、Eq、RS485、2DI | AMR-C9E7M1 | AMR-C9C7M1 | Outgoing circuit | There are communication, telemetry, and remote signaling |
3I、3U、P、Q、S、PF、Ep、Eq、RS485、2DI | AMR-C9E9M1 | AMR-C9C9M1 | Incoming and outgoing circuit | There are communication, telemetry, and remote signaling |
3I、3U、P、Q、S、PF、Ep、Eq、H、RS485、2DI | not have | AMR-C9C9MH1 | Incoming and outgoing circuit | Communication, telemetry, remote signaling, harmonics |
3I、RS485、2DI、2DO | AMR-C9E1M3 | AMR-C9C1M3 | Outgoing circuit | There are communication, telemetry, remote signaling, and remote control |
3U、RS485、2DI、2DO | AMR-C9E2M3 | AMR-C9C2M3 | Outgoing circuit | There are communication, telemetry, remote signaling, and remote control |
3I、3U、RS485、2DI、2DO | AMR-C9E3M3 | AMR-C9C3M3 | Outgoing circuit | There are communication, telemetry, remote signaling, and remote control |
3I、3U、Ep、Eq、RS485、2DI、2DO | AMR-C9E7M3 | AMR-C9C7M3 | Outgoing circuit | There are communication, telemetry, remote signaling, and remote control |
3I、3U、P、Q、S、PF、Ep、Eq、RS485、2DI、2DO | AMR-C9E9M3 | AMR-C9C9M3 | Incoming and outgoing circuit | There are communication, telemetry, remote signaling, and remote control |
3I、3U、P、Q、S、PF、Ep、Eq、H、RS485、2DI、2DO | not have | AMR-C9C9MH3 | Incoming and outgoing circuit | Communication, telemetry, remote signaling, remote control, harmonics |
Electrical symbol annotation table | |||||
code | Function Description | notes | code | Function Description | notes |
I | electric current | 3I | three-phase current | ||
U | voltage | 3U | phase voltage | ||
P | active power | PF | Power factor | ||
Q | reactive power | F | frequency | ||
S | apparent power | H | harmonic | ||
Ep | Active energy | Eq | Reactive energy | ||
Ep* | Time-sharing active electricity | Eq* | Time-sharing reactive power | ||
Classification of AMR series intelligent digital electric meter product types | |||||
classification basis | type | Example of Model | notes | ||
Number of phases | three-phase | AMR-C9E9M3 | |||
single phase | AMR-A4E1M3 | ||||
display technique | LED digital display | AMR-C9E9M3 | |||
LCD display | AMR-C9C9M3 | ||||
Installation method | Embedded installation | AMR-C9E9M3 | Need to open a hole, | ||
Rail mounted installation | AMR-A3C5M | No drilling required, 35mm guide rail needed | |||
External dimensions | Three phase: 96, 72 | AMR-C9E9M3 | There is a guide rail type | ||
Single phase: 48 | AMR-A4E1M3 | There is a guide rail type | |||
Time-sharing electricity | With time-sharing electricity | AMR-C9EAM3 | |||
Timeless electricity | AMR-C9E9M3 | ||||
harmonic measurement | Measurement with harmonics | AMR-C9C9MH3 | |||
No harmonic measurement | AMR-C9C9M3 | ||||
analog output | Equipped with analog output | AMR-C9E9M1A | |||
No analog output | AMR-C9E9M1 | ||||
communication | Equipped with communication function | AMR-C9E9M | |||
No communication function | AMR-C9E9 | ||||
I/O function | Equipped with I/O function | AMR-C9E9M3 | |||
No I/O function | AMR-C9E9M | ||||
explain: | |||||
1. According to the project situation, the design department and relevant personnel of the user unit can choose the model based on the naming rules of product samples. | |||||
2. It is recommended to choose an intelligent digital meter with three remote functions in the project for future SCADA, BAS, or DCS systems. | |||||
3. If you have any questions, you can consult the business representative of Shanghai Aimeng Electromechanical Technology Co., Ltd. or inquire by phone.
The original AMR-C9E1 series, AMR-C9E2 series, AMR-C9E3 series, AMR-C9E4 series, AMR-C9E5 series, AMR-C9E6 series, AMR-C9E7 series, AMR-C9E8 series, AMR-C9E9 series, AMR-C9EA series, and other products have all been upgraded. Please contact the company or local distributor in a timely manner.
|
For other parameters, please consult the company's relevant sales or browse the product manual!
The product has been upgraded, please contact the company promptly