●summary
Digital measurement and control power instruments are a series of products designed for the power measurement and control needs of power systems, industrial and mining enterprises, and other industries. It can measure many commonly used power parameters with high precision, such as three-phase voltage, three-phase current, three-phase voltage current combination, three-phase active power, etc. It also has four switch input measurement functions (realizing "shaking signal") and 2-3 relay circuit output functions (realizing "remote control") with RS-485 digital interface, and uses standard MODBUS-RTU protocol to achieve "shaking measurement" function. The variable ratio communication parameters can be programmed and set through the instrument panel buttons, making it flexible and convenient to use.
●TECHNICAL INDEX
|
Indicator
|
|
accuracy class
|
Level 0.5, 0.2, frequency meter level 0.1
|
|
Display
|
Four digit LED display with additional symbol bit
|
|
Input
|
Nominal input
|
Current AC1A, AC5A, DC20mA, etc; Voltage AC100V, AC220V, AC380V, DC75mV, etc
|
overrange
|
Continuous: 1.2 times, instantaneous: current 10 times (5 seconds), voltage 2 times (10 seconds)]
|
|
Frequency
|
50/60Hz±10%
|
|
Power supply
|
Auxiliary power supply
|
AC、DC 80~270V
|
Power consumption
|
≤4VA
|
|
Relay
|
2-3 relay outputs, relay contact capacity: AC5A/250V resistive, DC5A/30V resistive
|
|
Switching input
|
4-channel switch input dry node mode, connected when Ri<500 Ω; Ri>100k Ω disconnect
|
|
Isolation and voltage resistance
|
Input and power>AC2kV, input and output>AC1kV, power and output>AC2kV, output and output>1kV
|
|
insulation resistance
|
≥100MΩ
|
|
Mean time between failures
|
≥50000h
|
|
Communication output
|
RS-485 interface, MODBUS-RTU protocol, address: default 1 (1-256 optional)
Baud rate: default 9600 (optional 48009600) bps
|
●96 Square Digital Measurement and Control Instrument Model, Function List (Hole Size: 92 X 92)
model | type | measure | Peripheral functions (optional, to be specified when ordering) | ||
Relay | Switch Module | digital communication | |||
ELA194I-9S1 | AC ammeter | Single phase IL | 2 routes | Four channel switch input | RS485 communication (optional) |
ELA194I-9S4 | AC ammeter | Three phase Ia, Ib, Ic | 3 routes | ||
ELA195I-9S1 | DC ammeter | Single phase IL | 2 routes | ||
ELZ194U-9S1 | AC Voltmeter | Single phase ULN | 2 routes |
ELZ194U-9S4 | AC Voltmeter | Three phase U1, U2, U3 | 3 routes | Four channel switch input | RS485 communication (optional) |
ELZ195U-9S1 | DC voltmeter | Single phase ULN | 2 routes | Four channel switch input | |
ELS194P3(P4)-9S1 | active power meter | Three phase kW | 2 routes | ||
ELS194Q3(Q4)-9S1 | varmeter | Three phase KVAR | 2 routes | ||
ELD194F-9S1 |