Beijing Hengtai Ruibo Technology Development Co., Ltd
Home>Products>550A-25 dissolved oxygen measuring instrument
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13466450537
  • Address
    Shoukai Smart Society
Contact Now
550A-25 dissolved oxygen measuring instrument
Introduction to YSI550A Dissolved Oxygen Analyzer
Product details

550A-25 dissolved oxygen measuring instrument

Introduction to YSI550A Dissolved Oxygen Analyzer

The YSI 550A adopts a fully waterproof (IP67 waterproof rating) and impact resistant instrument housing, and features an innovative field replaceable dissolved oxygen electrode module. Using YSI's proven polarographic technique and YSI's globally renowned thermistor technique, dissolved oxygen and temperature can be measured simultaneously. The new generation of PE cover film provides faster reaction time and lower stirring dependence.


YSI550A Portable Dissolved Oxygen Analyzer Product Features:

◆ Fully waterproof, compliant with IP67 waterproof rating

◆ Field replaceable dissolved oxygen electrode module

Faster reaction time, lower stirring dependence

Stainless steel probe, sturdy and durable, easier to sink into water

Install stress relievers at both ends of the cable interface to reduce material fatigue at the connection and effectively extend the cable's lifespan

◆ Built in dissolved oxygen calibration room/probe storage room, convenient to carry and maintain the normal working state of the probe

◆ Available with 3.7, 7.5, 15, and 30 meter cables for selection

The measurement range of dissolved oxygen has been expanded to 50 milligrams per liter

◆ Air saturation or milligram/liter calibration mode

◆ 2000 hours of ultra long battery life

YSI550A Technical Parameters:

YSI 550A System Specifications

Technical indicators for measuring parameters

temperature

measuring range
resolution
accuracy

-5 to+45 ℃
0.1℃
±0.3℃

dissolved oxygen
(% air saturation)

measuring range
resolution
accuracy

0 to 500%
0.1% or 1% air saturation (optional)
0 to 200%: ± 2% of the reading or 2% air saturation, whichever is greater;
200 to 500%: ± 6% of reading

dissolved oxygen
(milligrams per liter)

measuring range
resolution
accuracy

0 to 50 milligrams per liter
0.01 or 0.1 milligrams per liter (optional)
0 to 20 milligrams per liter: 0.3 milligrams per liter or ± 2% of the reading, whichever is greater;
20 to 50 milligrams per liter: ± 6% of the reading

Note: The instrument accuracy specification is the sum of the host and probe