Equipment use: The high and low temperature alternating test chamber is a testing equipment used in aviation, automotive, home appliances, scientific research and other fields to test and determine the parameters and performance of electronic, electrical and other products and materials after high temperature, low temperature, or constant temperature environmental changes.
The high and low temperature alternating test chamber is used to simulate the heat resistance, moisture resistance, cold resistance, dry resistance, and quality management of products under a combination of climate and humidity conditions (high and low temperature operation and storage, temperature cycling, high temperature and high humidity, low temperature and low humidity, condensation testing, etc.). It is applied in the industrial, aerospace industry, automation components, automotive components, electronic and electrical components, instruments and meters, materials, plastics, chemical, food, pharmaceutical industries, and related products to evaluate the adaptability and characteristics of the tested products under given environmental conditions.
The high and low temperature wet heat test meets the standard:
1. GB10592-2008 Technical Conditions for High and Low Temperature Test Chambers (Temperature Changes) 2. GB/T2423.1-2008 Environmental testing for electrical and electronic products Part 2: (IEC60068-2-1:2007) Test A: Low temperature test method 3. GB/T2423.2-2008 Environmental testing for electrical and electronic products Part 2: (IEC60068-2-1:2007) Test B: High temperature test method 4. GB/T2423.3-2006 Environmental testing for electrical and electronic products Part 2: (IEC60068-2-78:2001) Test Cab: Constant test method 5. GB/T2423.4-2008 Environmental testing for electrical and electronic products Part 2: (IEC60068-2-30:2005) Test Db: Alternating current test method 6. GB/T2423.9-2001 Environmental Testing for Electric and Electronic Products Part 2: (IEC60068-2-4) Test Cb: Alternating Damp Heat Test Method 7. GB/T2423.22-2002 Environmental testing for electrical and electronic products Part 2: (IEC68-2-14) Test N: Temperature variation 8. GJB150.3A-2009 Military Equipment Laboratory Environmental Test Methods Part 3: High Temperature Test Methods 9. GJB150.4A-2009 Military Equipment Laboratory Environmental Test Methods Part 3: Low Temperature Test Methods 10.GB 24977-2010 11.GB/T 4893.7-2013 |
Conventional specifications and dimensions:
Volume (L) |
Inner box dimensions mm width depth height |
Outer box dimensions mm width depth height |
Total power KW |
Temperature and humidity range |
50L |
360*350*400· |
830*880*1500 |
3.6~10.5 According to the volume of the box Pending adjustable |
Temperature range: (0~+160℃ -20~+160℃ -40~+160℃ -60~+160℃ -70~+160℃ -82-+160℃) Humidity range: (20%-98%RH) |
100L |
500*400*500 |
980*920*1600 |
||
150L |
500*500*600 |
980*1000*1700 |
||
250L |
600*500*750 |
1080*1050*1860 |
||
400L |
800*600*850 |
1280*1100*2000 |
||
500L |
800*700**900 |
1280*1200*2050 |
||
800L |
1000*800*1000 |
1480*1300*2150 |
||
1000L |
1000*1000*1000 |
1480*1500*2150 |
||
Multiple specifications and models to choose from |
Our company can customize dimensions, modify and strengthen according to the requirements of experimental use |
|||
performance parameter |
||||
temperature fluctuation |
≤±0.5℃ |
|||
temperature uniformity |
≤±1℃ |
|||
precision |
0.1℃ |
|||
Heating rate (min) |
3℃~5℃ |
|||
Cooling rate (min) |
0.7℃~1.0℃ |
|||
Humidity range |
20%-98%RH(Can be adjusted within the range of 10% -98% RH according to the experimental requirements) |
|||
Humidity fluctuation |
≤± 2% RH (humidity above 75% RH) ± 3-5% RH |
|||
Need for rapid temperature change |
Rapid cooling: 3-5 ℃/min; Rapid heating: 3-5 ℃ min |
Consultation with customer service for customization |
||
Construction | ||||
Inner box material |
SUS3041.5mm stainless steel plate (mirror/matte) |
|||
External material |
1.5mm cold-rolled steel plate/stainless steel wire drawing, electrostatic spraying, sturdy, beautiful, and durable. |
|||
Insulation material |
Fiberglass cotton/polyurethane foam material, thickness 100mm |
|||
heater |
Stainless steel nickel chromium alloy finned ceramic heater |
|||
Wind cycle |
Stainless steel long shaft motor, stainless steel multi wing centrifugal fan bladegroundsEnsure proper circulation of the built-in air duct in the test chamber |
|||
Sealing material |
Silicone rubber, reliable sealing |
|||
Lead test empty |
Ø 50mm~Ø 100mm default left side can be located at any position according to usage requirements |
|||
Observation window |
Large rectangular multi-layer hollow electric heating glass observation window withHigh and low temperature resistant lighting deviceLED lighting can clearly observe internal tests,Observe the heating function of the window glass. It can prevent condensation and frosting during low-temperature testing. |
|||
carrier |
Equipped with two partitions, it can be freely adjusted in height for loading and unloading, and is convenient for cleaning inside the box (can be customized according to the reinforcement of the test item) Standard Load Capacity: 50KG Box Bottom Load Capacity: 150KG |
|||
Bottom casters |
The bottom of the equipment is designed with four sets of universal casters, which can be moved, fixed, and adjusted up and down smoothly |
|||
Humidification/dehumidification water replenishment system |
||||
Humidification method |
External electric heating and humidification method Stainless steel armored electric heater Humidifier control mode: PID control mode Water level control device, heater anti dry burning device with water shortage alarm indication |
|||
Water supply system |
Built in water tank, supplying water to the system through a circulating pump, can be connected to an external water source, and has a water shortage alarm indicator |
|||
Water tank drainage |
When the water tank of the test box needs to be cleaned or not used for a long time, the water in the tank can be drained through the manual valve installed at the back of the box |
|||
Drainage inside the box |
There is a drainage outlet behind the experiment, which can be connected to a pipe to discharge into the sewer pipe |
|||
Dehumidification method |
Mechanical refrigeration light pipe surface dehumidification, regulated by an evaporation pressure regulator to avoid frosting on the evaporator |
|||
control system | ||||
Control instruments |
7-inch true color touch screen control instrument, easy to operate, convenient to set, temperature control accuracy of 0.01 ℃, programming beyond 1200 segments The two control modes of program or fixed value can be freely converted, and the vertical curve temperature and humidity data can be stored for up to 6 months. |
|||
sensor |
-Suitable for Finnish Vaisala/Korean ternary at 50 ℃~70 ℃~+150 ℃; 0 ℃~-20 ℃~-40 ℃~+150 ℃ PT100 Platinum Resistance |
|||
Electrical components |
LG/S Naide/Delixi/Chint and other well-known brands, with stable and reliable performance |
|||
refrigeration system |
||||
compressor |
Adopting French 'Taikang' fully enclosed refrigeration compressor |
|||
refrigerant |
R404A R23 (fluorine free) |
|||
Cooling method |
Air cooling/water cooling |
|||
evaporator |
Internally threaded coil with turbulent aluminum fins, the refrigerant can continuously evaporate within the tube, resulting in more thorough evaporation. |
|||
other |
||||
power supply |
AC220V~AC380V 50HZ (optional) |
|||
Protection system |
Overtemperature protection, leakage protection, under phase protection |
|||
Missing item protection, overcurrent protection, fast fuse, compressor high and low voltage protection, compressor overheating protection, compressor overcurrent protection, line fuse and fully sheathed terminal, water shortage protection, grounding protection |
||||
Usage environment |
Temperature: 5 ℃~30 ℃, relative humidity: ≤, 85% RH |
|||
Installation ground |
The ground is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust There is no strong electromagnetic radiation source nearby Leave appropriate maintenance space around the equipment |
|||
Can provide third-party calibration reports |
Optional |