120ASX High Frequency Switching AC Power Supply, Pacific, USA
120ASX High Frequency Switching AC Power Supply, Pacific, USA
Product details

120ASX High Frequency Switching AC Power Supply, Pacific, USA

The ASX series is a high-performance switch mode AC power supply with output capacities ranging from 1.5kVA to 12kVA. Both single-phase and three-phase output models are provided. The company has designed the equipment appropriately, and its rated output value is determined by a comprehensive analysis of input power supply, output voltage, power factor, and temperature.

We emphasize the need to achieve low noise, easy installation, and maximum power in the smallest space. Control and operational performance provide testing engineers with multifunctional applications and simple usage methods. The application scope ranges from simple manual control of frequency conversion to harmonic testing and editable transient simulation.

The ASX series is a variable frequency power supply that utilizes advanced high-frequency pulse width modulation technology, featuring excellent heat dissipation, low noise, and high efficiency.
model rated
output
capacity
(VA)
output
Number of phases
(Note 1)
output
maximum
voltage
(VRMS)
(Note 2)
output
electric current
(ARMS)
input
Number of phases
(Note 4)
Panel height (U) Weight (LBS./KG.)
Single-stage model
115ASX 1500 132 16 3 65/29.5
120ASX 2000 150/300 20/14 3 75/34
140ASX 4000 135/270 32/16 5 120/54.5
160ASX 6000 132/264 48/16 5 145/66
three-stage model
315ASX 1500
132/264
132 (Vl-N)
12/6
4 per Ø
3 75/34
320ASX 2000
150/300
150 (Vl-N)
20/12
7 per Ø
3 85/38.5
345ASX 4500
135/270
135 (Vl-N)
36/12
12 per Ø
5 145/66
360ASX 6000
132/264
132 (Vl-N)
48/16
16 per Ø
5 145/66
390ASX 9000
135/270
135 (Vl-N)
72/36
24 per Ø
9 224/102
3120ASX 12000
135/270
135 (Vl-N)
96/48
32 per Ø
9 244/111

Optional transformer model coupled output voltage range

model
rated
output
capacity
(VA)
output
Number of phases
(Note 1)
Maximum output voltage (VRMS) (Note 2) Output current (ARMS) (Note 3)
input
Number of phases
(Note 4)
panel
height
(U)
Weight (LBS./KG.)
Single-stage model
Transformer Transformer
Direct 1:5:1 2:0:1 2:5:1 Direct 1:5:1 2:0:1 2:5:1
115ASXT 1500 132 198 264 330 16 10.7 8 6.4 3 80/36.4
140ASXT 4000 1Ø/2Ø 135/270 202/404 270/540 338/600 32/16 21.3/10.7 16/8 12.8/6.4 8 245/111.3
160ASXT 6000 1Ø/2Ø 132/270 198/396 264/528 330/600 48/16 32/10.6 24/8 19.2/6.4 8 270/122.8
three-stage model
Transformer Transformer
Direct 1:5:1 2:0:1 2:5:1 Direct 1:5:1 2:0:1 2:5:1
345ASXT
4500
1Ø/2Ø
3Ø
135/270
135/234
202/404
202/350
270/540
270/468
338/600
338/585
36/12
12/Ø
24/8
8/Ø
18/6
6/Ø
14.4/4.8
4.8/Ø
8 265/120
360ASXT
6000
1Ø/2Ø
132/264
132/228
198/396
198/343
264/528
264/457
330/600
330/572
48/16
16/Ø
32/10.7
10.7/Ø
24/8
8/Ø
19.2/6.4
6.4/Ø
8 270/122.8
390ASXT
9000
1Ø/2Ø
135/270
135/234
202/404
202/350
270/540
270/468
338/600
330/585
72/36
24/Ø
48/24
16/Ø
36/18
12/Ø
28.8/14.4
9.6/Ø
13 504/229
3120ASXT
12000
1Ø/2Ø
135/270
135/234
202/404
202/350
270/540
270/468
338/600
338/585
96/48
32/Ø
64/32
21.3/Ø
48/24
16/Ø
38.4/19.2
12.8/Ø
13 524/238

notes

  1. Note 1: All single-phase output devices have phase separation output capability (except for 115ASX), and all three-phase output devices have single-phase, three-phase, and phase separation output capabilities.
  2. The output voltage range and single-phase/three-phase switching can be selected through the front panel or programmable control.
  3. Note 2. The table lists the output voltage range of standard models. The maximum output voltage refers to the maximum voltage value that can be output when fully loaded and directly coupled within the rated input voltage range,
  4. Other output voltage ranges can be obtained through optional transformer modules.
  5. Note 3. Maximum pulse current that can be sustained.
  6. Note 4: The single-phase input voltage can be 100, 110, 120, 208, 200, 220, 240 VAC ± 10%. The three-phase input voltage can be 208, 220, 240, 380, 416 ± 10%.
  7. The input voltage can be selected as 480V input or 400Hz frequency input, but additional fees are required.

  • Product application characteristics

    • 22 sets of waveform library - arbitrary waveform generator
    • Operating frequency range from 15Hz to 1200 Hz - with an output bandwidth of 5000 Hz
    • Precise measurement and display of true RMS voltage, current, and power
    • Compatible with UPC Studio graphical user interface
    • Compatible with SCPI RS-232 interface
    • Switching single-phase/three-phase output through front panel or remote control
    • Store 99 sets of programs for steady-state and transient testing purposes
    • Provide LabVIEW for Windows ®/ LabWindows ® drive
    • Create waveform library through waveform synthesis function (optional)
    • Harmonic analysis of voltage and current
    • Measurement function of effective value and peak value
    • Continuous Voltage Self Calibration Function (CSC Function)
    • Precise programmable output voltage, with a control accuracy of up to 0.05% when selecting CSC function
    • Programmable output impedance function
    • Up to 0-300VAC directly coupled output
    • Capacity levels range from 1.5kVA to 12kVA
    • Calibration can be performed through external instruments
    • Can provide CE and ETL marks

    The design provides complete control over the AC power supply

    • All ASX series AC power supplies can be equipped with a digital programmable controller or a manual controller.
    • A single-phase AC power supply can provide voltage outputs of 0-135VAC or 0-270VAC. The three-phase AC power supply can freely switch between three-phase or single-phase output voltage forms.
    • The ASX series AC power supply can be selected to use direct coupling or transformer coupling output through the front panel or remote control.
    • All functional operations can be controlled through the front panel or remote RS-232 or IEEE488.2/SCPI BUS. Can provide LabVIEW for Windows ® And LabWindows ® Drive of the device.

    ASX series special operation functions

    Continuous voltage self calibration function
    This feature provides additional accuracy for AC output voltage. When turned on, the accuracy can reach ± 0.1% of the internal voltage meter of the power supply as a reference.

    Programmable dynamic output impedance (optional)
    This function enables the operator to dynamically control the output impedance of the AC power supply. By using the output current as the feedback signal in the output voltage circuit, both positive and negative impedances can be edited. This control simulates and compensates for high peak currents, distortions, or transformer losses within ± 10% of the output voltage.

    This function generates positive, negative, or zero output impedance (Zo).
    • Compensated for line distortion and losses caused by transformers.
    • Simulate power supply ramp up for product testing, with a compensation range of ± 10% of the output voltage.
    Waveform library
    Up to 22 different waveforms can be stored in the waveform library for replacement as part of a stable or transient program or as part of a transient test program in any output phase. The waveform library with storage location 1 is a high-resolution sine wave waveform that cannot be edited. The waveform library with storage locations 2-22 can be edited and replaced at will. For power supplies that use a programmable controller UPC, the waveform library can be stored infinitely in the computer.

    Waveform Editing
    The fully functional waveform editor allows modification of stored waveforms in both time and frequency domains. This method can quickly generate spikes, drops, notches, and other forms of waveforms. Therefore, the modified waveform can be used for steady-state or transient programs.
    Waveform analysis (optional feature of UPC 1/3)
    Provide harmonic content analysis of voltage or current waveforms and display it in graphical or numerical form. The data of each harmonic is displayed in percentage, and the total harmonic distortion, total odd harmonic distortion, and total even harmonic distortion are also displayed in percentage.

    Waveform synthesis (optional function of UPC 1/3)
    Provide simple and fast testing capabilities for AC harmonic distortion waveforms. This function can be easily achieved by inputting the distortion rate and phase angle of the 2nd to 51st harmonics of the fundamental wave.

    Transient response based on time
    Transient responses can be created and executed within the specified time range to change the output voltage, output frequency, and output waveform.

    Transient response based on cycles
    Create and execute transient responses within the first to 100th cycles to change the output voltage, output frequency, and output waveform.
  • application

    AC test power supply
    The ASX series AC power supply equipped with powerful microprocessors can be used to build a complete integrated testing system. It can provide multiple power testing conditions for the device under test and measure and analyze the output performance parameters.

    Frequency/Voltage Conversion
    The ASX series AC power supply can provide stable AC voltage output within the frequency range of 15 to 1200Hz. The maximum voltage can reach 600VAC. The output frequency is obtained through a quartz crystal oscillator.

    phase-switching
    With single-phase and three-phase output capabilities, the ASX series AC power supply can achieve any phase switching from single-phase to three-phase or from three-phase to single-phase.

    Controller Selection Wizard

    The ASX series can use four controller models. This includes single-phase and three-phase models for manual and programmable control.
    • UPC-1M, Single phase manual control, 15 Hz to 1200 Hz
    • UPC-3EM, Three phase manual control, 15 Hz to 1200 Hz
    • UPC-1, Single phase programmable control, 15 Hz to 1200 Hz
    • UPC-3E, Three phase programmable control, 15 Hz to 1200Hz
    All controllers can be manually operated through the front panel. The programmable controller can be controlled through the front panel or remote interface. RS232 is the standard interface, and IEEE488.2 is the optional interface.
  • Power specifications

    Output frequency:
    15 to 1200Hz full power

    Input power regulation rate:
    Less than 0.1% under ± 10% input voltage variation

    Load stabilization rate:
    0.25% (15 to 400Hz); 0.50% (400 to 1200Hz). Less than 0.1% (CSC ON).

    Output distortion rate:
    0.25% THD (15 to 200Hz), 0.5% THD (200 to 1200Hz).

    Ripple and noise:
    -66 dB

    Response time:
    The typical value for 10-90% load with step changes is 60 µ sec.

    Institutional specifications

    All models are designed with a 19 inch standard cabinet. Products with a capacity of over 4000VA are equipped with handles for easy handling.

    Installation:
    A standard 19 inch cabinet. All models can choose appropriate sliding rails according to requirements.

    Height:
    Please refer to the model table to obtain the panel height.

    Depth:
    The distance from the front panel to the back panel, including connectors, handles, and cables, shall not exceed 24 inches.

    dissipate heat:
    The forced air cooling method of blowing air from the front or side and blowing air from the back can dissipate heat. The use of temperature controlled speed regulating fans can reduce noise and extend the life of electric fans.

    Increase output voltage range (optional transformer module)

    The ASX series AC power supply can be equipped with an output transformer to increase the output voltage range. The output range of direct coupling or transformer coupling can be changed through the front panel or remote commands. The standard output frequency range under transformer coupling output conditions is 45 to 1200 Hz. The standard transformer output ratios are 1.5:1, 2.0:1, and 2.5:1. Transformer output is achieved by internal or external transformer modules. If you need more information on special output voltage ranges, please contact our company.

    UPC controller specifications

    The new UPC controllers of the Pacific Power family include UPC-1M, UPC-3EM, UPC-1, and UPC-3E. The UPC controller is a modular component in the ASX series AC power supply, which can achieve any setting from single-phase to three-phase and from manual control to programmable control. The following table lists the key performance of various types of UPC controllers.

    All UPC controllers have precise measurement functions and are equipped with a 160 character LCD display, as well as a 30 key front panel control, making the controller more powerful and user-friendly.
    The UPC-1 and UPC-3E controllers can be equipped with remote control interfaces via RS-232 or GPIB, which are compatible with SCPI's instruction architecture. The RS-232 interface of the serial port can work up to 38.4kB/s, and GPIB is compatible with IEEE-488.2.

    Frequency:
    Range: 15 to 1200 Hz. Resolution: 4 significant digits, such as 50.00, 400.0, etc. Accuracy: ± 0.01%

    Output voltage (direct coupling):
    Scope: Programmable control, 0-Vmax, varying in 0.1V voltage steps. Accuracy: When performing continuous voltage self calibration, the output voltage accuracy is ± 50mVAC (0.05%) of the measured voltage on the machine

    Phase angle:
    For the UPC-3E controller, the phase angles of phases B and C relative to phase A can be edited in increments of 1 °± 0.5 ° from 0-359 °.

    Programmable current limit:
    The UPC-1 and UPC-3E controllers provide editable current limiting functions. The editing range is from zero to peak current, which is the maximum current value of the power supply.

    voltmeter:
    Range: 0 to 354VL-N, 0 to 708VL-L
    Resolution: 0.10VAC (front panel), 0.001VAC (remote)
    Accuracy: ± 0.2% (range value+calibration reference value)

    ammeter:
    Scope: 300% of the rated current of the system
    Resolution: 0.01VAC (front panel), 0.001VAC (remote)
    Accuracy: ± 0.2% (range value+calibration reference value)

    Power meter:
    Scope: Based on the range of the ammeter
    Resolution: 1.0W or VA (front panel or remote)

    Power factor:
    Calculate and display three significant digits.

    Expand the AC power supply into the automatic testing system

    Pacific Power Company's intelligent AC power supply enables engineers to use LabVIEW for Windows ® Or LabWindows ® Simplify automated testing operations for the required tests. Many virtual devices are compatible with Pacific Power Company's ASX series AC power supply.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!