1200 ℃ Double Tube Sliding Single and Multi Temperature Zone CVD System
Product Usage: This CVD system is specifically designed for growing thin films on metal foils, especially for research on flexible metal foil electrod
Product details

Product Usage:

This CVD system is specifically designed for growing thin films on metal foils, especially for the application of flexible metal foils in the new generation of energy

Research on electrodes achieves rapid heating and cooling through sliding furnaces.

Product composition:

CVD system configuration:

1. 1200 degree open vacuum tube furnace (optional single temperature zone and dual temperature zone).

2. The sliding system is divided into manual and electric sliding, and is equipped with an air-cooled system.

3. The inner and outer quartz tubes are connected with vacuum permeable atmosphere double flanges.

4. Multi channel gas flow control system (proton flow controller and float flow controller)

5. Vacuum system (optional with medium or high vacuum)

Product features:

Product uniqueness

The control circuit adopts fuzzy PID programming technology, which has high temperature control accuracy, small thermal inertia, no temperature surge, reliable performance, and simple operation.

The flange structure of the 2-way quick connection adopts our company's unique intellectual property patent design to improve operational convenience.

The three vacuum systems have automatic control functions for the upper and lower limits of vacuum degree. The high vacuum system uses a high-pressure, impact resistant molecular pump to prevent accidental air leakageCausing damage to the molecular pump and prolonging the service life of the system.

The 4 (electric) sliding system adopts a temperature controller to automatically control the movement of the furnace body. After the program is completed, the furnace body slides at the set speed due to the sliding limitFunction: The furnace body will not collide, and after the sample is exposed from the furnace body, it will be quickly cooled down through an air cooling system.

5 double tube vacuum sealed flanges, the reaction gas can react between the inner and outer tubes, and the cooling gas can pass through the inner tube, thereby reducing the temperature of the outer wall of the inner tube.

System name

1200 ℃ Double Tube Sliding Single/Multi Temperature Zone CVD System

system model

CVD-12II6SH-3Z/G

CVD-12III9SH-3Z/G

maximum temperature

1200℃

Heating zone length

610mm

940mm

Length of constant temperature zone

400mm

700mm

temperature range

Dual temperature zone

Three temperature zones

Quartz tube diameter

Inner tube: Φ 80mm Outer tube: Φ100mm

rated power

4.8Kw

7.2Kw

rated voltage

220V

380V (three-phase)

Sliding Distance

485mm

650mm

Sliding method

Manual sliding/automatic sliding (automatically controlled by temperature controller, when the program is completed, the furnace slides at the set speed)

temperature control

Domestic program-controlled temperature control system with 50 segments of program-controlled temperature control;

Control accuracy

±1℃

Maximum operating temperature of furnace tube

<1200℃

Double tube flange connection

Adopting double flange and double clamp connection, it can expand multiple functions and independently control the vacuum and gas flow of the inner and outer pipes The connection between the sealing flange and the pipe fittings adopts multi ring sealing technology, forming a seal between the sealing flange and the outer wall of the pipe. The seal is still effective even in the case of large errors in the outer diameter of the pipe fittings. The installation of this sealing flange only needs to be done during the first use of the equipment

Gas control method

Mass flowmeter

Number of gas paths

3 channels (the number of air channels can be selected according to specific needs)

Flow range

0-500sccm (standard milliliters/minute, optional) nitrogen calibration

accuracy

±1%F.S

response time

≤4sec

operation temperature

5-45℃

Working pressure

Inlet pressure 0.05-0.3Mpa (gauge pressure)

System connection method

Using KF quick connect bellows, high vacuum manual baffle valve, and digital vacuum measuring instrument

specifications

high vacuum

System vacuum range

1x10-3Pa-1x10-1Pa

vacuum pump

Theoretical limit vacuum degree of vacuum molecular pump
5x10-6Pa pumping rate 1600L/S
Rated voltage 220V, power 2Kw

External dimensions of furnace body

480×770×605mm

410×1100×605mm

System external dimensions

530 × 1440 × 750mm (excluding high vacuum)

Total weight of the system

340Kg