Nanning Benru Electromechanical Equipment Wholesale Department
Home>Products>(Coal Safety Certificate) DF25-80X6 stainless steel multi-stage centrifugal pump
(Coal Safety Certificate) DF25-80X6 stainless steel multi-stage centrifugal pump
Model parameters: Flow rate Q2-25m3/h Head H84-476m Example: DF25-80X6DF - represents multi-stage corrosion-resistant centrifugal pump 25- represents
Product details

(煤安证)多级泵

Model parameters:

Flow rate Q 2-25m3/h

Lift H 84-476m

Example: DF25-80X6

DF - stands for multi-level corrosion resistancecentrifugal pump

25- represents the flow rate of the pump (m3/h)

80- represents the single-stage head of the pump (m)

6- represents the number of stages of the pump

Overview of DF25-80X6 stainless steel multi-stage centrifugal pump:

The DF25-80X6 stainless steel multi-stage centrifugal pump adopts the hydraulic model of high-efficiency and energy-saving products recommended by the country, and is in a leading position in the industry in terms of technology. It has the advantages of high efficiency, wide performance range, safe and stable operation, low noise, long service life, and easy installation and maintenance. Our company has passed the IS09001:2000 quality system certification, and our product design, production, and service have strict and standardized control systems, ensuring sufficient product quality assurance.

DF25-80X6 stainless steel multi-stage centrifugal pump parameter range

Flow rate Q 2-25m3/h

Lift H 84-476m

Model Description of DF25-80X6 Stainless Steel Multistage Centrifugal Pump

DF25-80X6

DF - stands for multi-stage corrosion-resistant centrifugal pump

25- represents the flow rate of the pump (m3/h)

80- represents the single-stage head of the pump (m)

6- indicates that the number of stages of the pump is 6

DF25-80X6 stainless steel multi-stage centrifugal pump rotation direction:

The pump rotates clockwise when viewed from the motor end.

DF25-80X6 stainless steel multi-stage centrifugal pump complete set scope:

DF type stainless steel pump can be supplied with motor and base, and can be equipped with a common base or its own base. The manufacturer can also provide accessories (including discharge cone tube, gate valve, check valve) and spare parts (including impeller, sealing ring, guide vane sleeve, balance disc, shaft sleeve).

DF25-80X6 stainless steel multi-stage centrifugal pump structural type

The DF stainless steel pump is a single suction, multi-stage, and segmental multi-stage centrifugal pump. This pump type is horizontally installed, centrally supported, with horizontal suction and vertical discharge. Shaft seals generally use packing seals, and mechanical seals or other seals can also be used according to user needs. The bearings are lubricated with grease. The axial force of the pump is balanced by a balance plate mechanism.

Structural diagram of DF25-80X6 stainless steel multi-stage centrifugal pump

DF25-80X6 stainless steel multi-stage centrifugal pump product application

1. Water supply: filtration and transportation of water plants, water supply to different zones of water plants, main pipeline pressurization, and pressurization of high-rise buildings.

2. Industrial pressurization: process water system, cleaning system, high-pressure flushing system, fire protection system.

3. Industrial liquid transportation: cooling and air conditioning systems, boiler feedwater and condensing systems, machine tool matching, and transportation of acidic and alkaline media.

4. Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator, and water treatment system for swimming pools.

5. Irrigation: farmland irrigation, sprinkler irrigation, drip irrigation.

Operation precautions for DF25-80X6 stainless steel multi-stage centrifugal pump

1. Starting conditions for DF25-80X6 stainless steel multi-stage centrifugal pump

a、 Stainless steel is only allowed to operate within the specified parameter range;

b、 Stainless steel pumps are not allowed to operate with the discharge valve closed or closed to a very small opening. Otherwise, it will cause the pump to heat up and reduce its lifespan. If the pump is installed in a parallel system, each pump must operate under specific parameters to ensure the flow rate of the pump;

c、 stainless steelMulti-stage pumpCannot close the suction valve for operation. Otherwise, it will cause the pump to run dry, resulting in damage to the pump components;

d、 The medium conveyed by the pump cannot contain air or gas, otherwise it will make it impossible to accurately measure the flow rate and head of the pump, and it will also cause grinding and damage to the parts.

2. Inspection before starting DF25-80X6 stainless steel multi-stage centrifugal pump

A、 Before starting the pump, the rotor should be turned to check if it is flexible;

B、 Check whether all bolts and pipeline leads are securely connected and the safety situation around the pump;

C、 Check if all instruments, valves, and devices are functioning properly

D、 Check whether the position of the oil ring and the oil level of the oil level gauge are normal;

e、 Check if the direction of the electric motor is consistent with the direction of the pump.

Installation dimension diagram of DF25-80X6 stainless steel multi-stage centrifugal pump

DF25-80X6 stainless steel multi-stage centrifugal pump external installation diagram (base itself)

DF25-80X6 stainless steel multi-stage centrifugal pump external installation drawing (common base)

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!